BACKGROUND AND OBJECTIVE: Photorefractive keratectomy (PRK) has been extensively evaluated for the correction of myopia. This study was undertaken to assess the safety, efficacy, and reliability of PRK in the correction of hyperopia. PATIENTS AND METHODS: There were 28 eyes with refractions of +1 to +7.75 D treated for hyperopia with the Chiron Technolas 217-C excimer laser. Thorough visual assessments were made before treatment and at regular follow-up to 18 months. Complications and patient satisfaction were noted. RESULTS: At 18 months the mean subjective refraction was +0.45+/-1.00 D with 26 eyes (92.8%) within 1 D of emmetropia. Thirteen eyes (46.4%) achieved uncorrected visual acuity (UCVA) of 20/20 or better and all patients had an UCVA of greater than or equal to 20/32 or better. Best corrected visual acuity (BCVA) remained unchanged in 26 eyes (92.8%) and improved in 2 eyes (7.2%). On the seventh day from treatment, 17 eyes (25%) had a loss of 2 or more lines of BCVA. At 15 days this was reduced to 8 eyes (14.3%) and at one month to 3 eyes (3.6%). There were no cases of loss of 2 or more lines of BCVA at 18 months of follow-up. All patients expressed a high degree of satisfaction. CONCLUSIONS: Photorefractive keratectomy safely and effectively reduced hyperopia in the patients studied. The technique was reliable and still offered good results at 18 months of follow-up.

Excimer laser photorefractive keratectomy for hyperopia / Pacella, Elena; Abdolrahimzadeh, S.; BALACCO GABRIELI, Corrado. - In: OPHTHALMIC SURGERY AND LASERS. - ISSN 1082-3069. - STAMPA. - 32:1(2001), pp. 30-34.

Excimer laser photorefractive keratectomy for hyperopia

PACELLA, Elena;S. Abdolrahimzadeh;BALACCO GABRIELI, Corrado
2001

Abstract

BACKGROUND AND OBJECTIVE: Photorefractive keratectomy (PRK) has been extensively evaluated for the correction of myopia. This study was undertaken to assess the safety, efficacy, and reliability of PRK in the correction of hyperopia. PATIENTS AND METHODS: There were 28 eyes with refractions of +1 to +7.75 D treated for hyperopia with the Chiron Technolas 217-C excimer laser. Thorough visual assessments were made before treatment and at regular follow-up to 18 months. Complications and patient satisfaction were noted. RESULTS: At 18 months the mean subjective refraction was +0.45+/-1.00 D with 26 eyes (92.8%) within 1 D of emmetropia. Thirteen eyes (46.4%) achieved uncorrected visual acuity (UCVA) of 20/20 or better and all patients had an UCVA of greater than or equal to 20/32 or better. Best corrected visual acuity (BCVA) remained unchanged in 26 eyes (92.8%) and improved in 2 eyes (7.2%). On the seventh day from treatment, 17 eyes (25%) had a loss of 2 or more lines of BCVA. At 15 days this was reduced to 8 eyes (14.3%) and at one month to 3 eyes (3.6%). There were no cases of loss of 2 or more lines of BCVA at 18 months of follow-up. All patients expressed a high degree of satisfaction. CONCLUSIONS: Photorefractive keratectomy safely and effectively reduced hyperopia in the patients studied. The technique was reliable and still offered good results at 18 months of follow-up.
2001
follow-up; keratoplasty; myopic astigmatism
01 Pubblicazione su rivista::01a Articolo in rivista
Excimer laser photorefractive keratectomy for hyperopia / Pacella, Elena; Abdolrahimzadeh, S.; BALACCO GABRIELI, Corrado. - In: OPHTHALMIC SURGERY AND LASERS. - ISSN 1082-3069. - STAMPA. - 32:1(2001), pp. 30-34.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/255581
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 3
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 15
social impact