There is a growing interest in indoor air quality for a better quality environment both at home and at work because many people spend at least 80% of their time indoors. The aim of our study was to evaluate the indoor concentration of airborne bacteria and fungi in a University auditorium, in an office of public buildings and in an apartment in the presence and in absence of building's occupants, building materials and furnishings. The concentrations of airborne bacteria and fungi were determined using a Surface Air System (SAS). In presence of people and furnishings the average air concentrations of bacteria (University auditorium: 925-1225 CFU m(-3); office: 493 CFU m(-3); apartment: 92-182 CFU m(-3)) were higher than in absence (respectively: 190-315 CFU m(-3); 126 CFU m(-3); 66-80 CFU m(-3)). The average air concentrations fungal were higher in presence of people and furnishings (University auditorium: 1256-1769 CFU m(-3);; office: 858 CFU m(-3); apartment: 147-297 CFU m(-3)) than in absence (respectively: 301-431 CFU m(-3):224 CFU m(-3); 102-132 CFU m(-3)). The obtained data can be considered as a step to identify acceptable levels for bioaerosols in common indoor environments.

Microbiological indoor air quality in healthy buildings / Sessa, Rosa; DI PIETRO, Marisa; Schiavoni, Giovanna; Santino, Iolanda; A., Altieri; S., Pinelli; DEL PIANO, Massimo. - In: NEW MICROBIOLOGICA. - ISSN 1121-7138. - 25:1(2002), pp. 51-56.

Microbiological indoor air quality in healthy buildings

SESSA, Rosa;DI PIETRO, Marisa;SCHIAVONI, Giovanna;SANTINO, Iolanda;DEL PIANO, Massimo
2002

Abstract

There is a growing interest in indoor air quality for a better quality environment both at home and at work because many people spend at least 80% of their time indoors. The aim of our study was to evaluate the indoor concentration of airborne bacteria and fungi in a University auditorium, in an office of public buildings and in an apartment in the presence and in absence of building's occupants, building materials and furnishings. The concentrations of airborne bacteria and fungi were determined using a Surface Air System (SAS). In presence of people and furnishings the average air concentrations of bacteria (University auditorium: 925-1225 CFU m(-3); office: 493 CFU m(-3); apartment: 92-182 CFU m(-3)) were higher than in absence (respectively: 190-315 CFU m(-3); 126 CFU m(-3); 66-80 CFU m(-3)). The average air concentrations fungal were higher in presence of people and furnishings (University auditorium: 1256-1769 CFU m(-3);; office: 858 CFU m(-3); apartment: 147-297 CFU m(-3)) than in absence (respectively: 301-431 CFU m(-3):224 CFU m(-3); 102-132 CFU m(-3)). The obtained data can be considered as a step to identify acceptable levels for bioaerosols in common indoor environments.
2002
air quality; bioaerosols; healthy buildings
01 Pubblicazione su rivista::01a Articolo in rivista
Microbiological indoor air quality in healthy buildings / Sessa, Rosa; DI PIETRO, Marisa; Schiavoni, Giovanna; Santino, Iolanda; A., Altieri; S., Pinelli; DEL PIANO, Massimo. - In: NEW MICROBIOLOGICA. - ISSN 1121-7138. - 25:1(2002), pp. 51-56.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/255028
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 49
  • ???jsp.display-item.citation.isi??? 41
social impact