A method based on liquid chromatography/mass spectrometry with an electrospray ion source and a single quadrupole instrument (LC/ES-MS) has been developed for determining trace levels of eight widely used penicillins in aqueous environmental samples. Analyte extraction was performed from 4 L tap water, 2 L groundwater, 1 L river water, 0.2 L treated sewage and 0.1 L raw sewage, by using a Carbograph 4 cartridge. During removal of the solvent, penicillins were purposely allowed to convert into their penicilloyl methyl esters. This 'in situ' derivatization step resulted in a dramatic enhancement of the response of the ES-MS system for non-amphoteric penicillins. Analyte recoveries were better than 80% irrespective of the type of aqueous sample, with the exception of amoxicillin (76%) and ampicillin (77%) in tap water. At the level of 50 ng/L of each analyte in ground water, the within-day precision was in the range 6-10%. Calibration curves were linear for injected amounts up to 800 ng, with R-2 in the range 0.9952-0.9995. When injecting large equivalent volumes of the aqueous samples, the electrospray matrix effect altered in-source collision-induced dissociation (CID) spectra of the analytes by severely weakening signals for fragment ions, as compared to spectra of reference standards. Remedies to obviate this anomalous unwelcome effect are suggested. On the basis of a signal-to-noise ratio of 10, limits of quantification were estimated to range between 2 (cloxacillin) and 24 ng/L (amoxicillin) in river water. Copyright (C) 2001 John Wiley & Sons, Ltd.

Method development for measuring trace levels of penicillins in aqueous environmental samples / Federica, Bruno; Curini, Roberta; DI CORCIA, Antonio; Nazzari, Manuela; Samperi, Roberto. - In: RAPID COMMUNICATIONS IN MASS SPECTROMETRY. - ISSN 0951-4198. - STAMPA. - 15:16(2001), pp. 1391-1400. [10.1002/rcm.381]

Method development for measuring trace levels of penicillins in aqueous environmental samples

CURINI, Roberta;DI CORCIA, Antonio;NAZZARI, Manuela;SAMPERI, Roberto
2001

Abstract

A method based on liquid chromatography/mass spectrometry with an electrospray ion source and a single quadrupole instrument (LC/ES-MS) has been developed for determining trace levels of eight widely used penicillins in aqueous environmental samples. Analyte extraction was performed from 4 L tap water, 2 L groundwater, 1 L river water, 0.2 L treated sewage and 0.1 L raw sewage, by using a Carbograph 4 cartridge. During removal of the solvent, penicillins were purposely allowed to convert into their penicilloyl methyl esters. This 'in situ' derivatization step resulted in a dramatic enhancement of the response of the ES-MS system for non-amphoteric penicillins. Analyte recoveries were better than 80% irrespective of the type of aqueous sample, with the exception of amoxicillin (76%) and ampicillin (77%) in tap water. At the level of 50 ng/L of each analyte in ground water, the within-day precision was in the range 6-10%. Calibration curves were linear for injected amounts up to 800 ng, with R-2 in the range 0.9952-0.9995. When injecting large equivalent volumes of the aqueous samples, the electrospray matrix effect altered in-source collision-induced dissociation (CID) spectra of the analytes by severely weakening signals for fragment ions, as compared to spectra of reference standards. Remedies to obviate this anomalous unwelcome effect are suggested. On the basis of a signal-to-noise ratio of 10, limits of quantification were estimated to range between 2 (cloxacillin) and 24 ng/L (amoxicillin) in river water. Copyright (C) 2001 John Wiley & Sons, Ltd.
2001
lc-esi-ms; penicillins
01 Pubblicazione su rivista::01a Articolo in rivista
Method development for measuring trace levels of penicillins in aqueous environmental samples / Federica, Bruno; Curini, Roberta; DI CORCIA, Antonio; Nazzari, Manuela; Samperi, Roberto. - In: RAPID COMMUNICATIONS IN MASS SPECTROMETRY. - ISSN 0951-4198. - STAMPA. - 15:16(2001), pp. 1391-1400. [10.1002/rcm.381]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/252961
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 37
  • ???jsp.display-item.citation.isi??? 35
social impact