In this paper a process for the treatment of landfill leachate involving evaporation and reverse osmosis was proposed. Experimental tests were performed on an industrial landfill leachate. The leachate was subjected to evaporation so as to obtain a distillate containing a small amount of organic material and a substantial amount of inorganic substances (consisting primarily of metals and ammonium salts). The distillate of the evaporation treatment was then subjected to reverse osmosis. The reverse osmosis tests were performed using two different membranes: the AD membrane (thin two-ply film of polyamide) and the SC membrane (thin three-ply film of polyamide). Tests carried out at different values of pH showed a reduction of organic content of about 88% when AD membranes were used and about 80% with SC membranes independently of pH. As regards ammonium, comparable reductions of over 97% were registered for both types of membrane in the optimal conditions of pH = 6.4 (97.1% for AD membranes and 97.7% for SC). (C) 2002 Elsevier Science Ltd. All rights reserved.

Treatment of industrial landfill leachate by means of evaporation and reverse osmosis / DI PALMA, Luca; Ferrantelli, Paola; Merli, Carlo; Petrucci, Elisabetta. - In: WASTE MANAGEMENT. - ISSN 0956-053X. - ELETTRONICO. - 22:8(2002), pp. 951-955. [10.1016/s0956-053x(02)00079-x]

Treatment of industrial landfill leachate by means of evaporation and reverse osmosis

DI PALMA, Luca;FERRANTELLI, Paola;MERLI, Carlo;PETRUCCI, Elisabetta
2002

Abstract

In this paper a process for the treatment of landfill leachate involving evaporation and reverse osmosis was proposed. Experimental tests were performed on an industrial landfill leachate. The leachate was subjected to evaporation so as to obtain a distillate containing a small amount of organic material and a substantial amount of inorganic substances (consisting primarily of metals and ammonium salts). The distillate of the evaporation treatment was then subjected to reverse osmosis. The reverse osmosis tests were performed using two different membranes: the AD membrane (thin two-ply film of polyamide) and the SC membrane (thin three-ply film of polyamide). Tests carried out at different values of pH showed a reduction of organic content of about 88% when AD membranes were used and about 80% with SC membranes independently of pH. As regards ammonium, comparable reductions of over 97% were registered for both types of membrane in the optimal conditions of pH = 6.4 (97.1% for AD membranes and 97.7% for SC). (C) 2002 Elsevier Science Ltd. All rights reserved.
2002
evaporation; landfill leachate; reverse osmosis; treatment
01 Pubblicazione su rivista::01a Articolo in rivista
Treatment of industrial landfill leachate by means of evaporation and reverse osmosis / DI PALMA, Luca; Ferrantelli, Paola; Merli, Carlo; Petrucci, Elisabetta. - In: WASTE MANAGEMENT. - ISSN 0956-053X. - ELETTRONICO. - 22:8(2002), pp. 951-955. [10.1016/s0956-053x(02)00079-x]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/250633
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 111
  • ???jsp.display-item.citation.isi??? 98
social impact