The first measurements of the spectral distribution of infrared radiation emitted by an undulator are reported. They are compared with calculations including both velocity and acceleration terms. Measurements have been performed at the beam line SIRLOIN (Spectroscopie en InfraRouge Lointain). The agreement between the observations and this first exact numerical solution shows that the inclusion of the velocity term in the submillimeter frequency range is necessary. Moreover, structures due to undulator edges are observed in the far infrared and mid-infrared range, while the interference pattern due to redshifted harmonics of the undulator is dominating in the mid-infrared to near infrared.

Spectral distribution of infrared synchrotron radiation by an insertion device and its edges: A comparison between experimental and simulated spectra / P., Roy; M., Cestelli Guidi; Nucara, Alessandro; O., Marcouille; Calvani, Paolo; P., Giura; A., Paolone; Y. L., Mathis. - In: PHYSICAL REVIEW LETTERS. - ISSN 0031-9007. - 84:3(2000), pp. 483-486. [10.1103/physrevlett.84.483]

Spectral distribution of infrared synchrotron radiation by an insertion device and its edges: A comparison between experimental and simulated spectra

NUCARA, Alessandro;CALVANI, Paolo;
2000

Abstract

The first measurements of the spectral distribution of infrared radiation emitted by an undulator are reported. They are compared with calculations including both velocity and acceleration terms. Measurements have been performed at the beam line SIRLOIN (Spectroscopie en InfraRouge Lointain). The agreement between the observations and this first exact numerical solution shows that the inclusion of the velocity term in the submillimeter frequency range is necessary. Moreover, structures due to undulator edges are observed in the far infrared and mid-infrared range, while the interference pattern due to redshifted harmonics of the undulator is dominating in the mid-infrared to near infrared.
2000
01 Pubblicazione su rivista::01a Articolo in rivista
Spectral distribution of infrared synchrotron radiation by an insertion device and its edges: A comparison between experimental and simulated spectra / P., Roy; M., Cestelli Guidi; Nucara, Alessandro; O., Marcouille; Calvani, Paolo; P., Giura; A., Paolone; Y. L., Mathis. - In: PHYSICAL REVIEW LETTERS. - ISSN 0031-9007. - 84:3(2000), pp. 483-486. [10.1103/physrevlett.84.483]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/248619
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 42
  • ???jsp.display-item.citation.isi??? 42