The infection of a prosthetic vascular graft (PVGI), although rare, is the most severe complication in reconstructive vascular surgery. The early diagnosis of this complication reduces the death rate from surgery. Aortofemoral graft infections differ clinically from peripheral graft infections in significant ways. The aim of this article is to evaluate separately the reliability of the Tc-99m-HMPAO-labeled leukocyte scan or white blood cell count (WBC) in the early detection of both aortofemoral and peripheral graft infections. Methods: One hundred sixty-two WBCs were performed on 129 consecutive patients with suspected aortofemoral (122 scans) and peripheral (40 scans) graft infection and in a 12-patient control group. Patients with suspected PVGI were categorized into three groups on the basis of their signs and symptoms on readmission: (a) patients with specific signs of graft infection (Group A); (b) patients with nonspecific signs of graft infection (Group B); and (c) patients with anastomotic aneurysms (Group C), Gram's stains of the perigraft exudate and graft cultures were performed and used as the gold standard in patients who underwent surgery. An 18-mo clinical follow-up was done to assess the presence or absence of graft infection in patients who did not have surgery. Results: In patients with suspected aortofemoral graft infections, the overall sensitivity, specificity and accuracy of WBCs (Groups A, B, C) were 100%, 92.5% and 97.5%, respectively, whereas sensitivity, specificity and accuracy calculated in the patients with nonspecific signs of graft infection (Groups B, C) were 100%, 92.3% and 96.9%, respectively. In patients with suspected peripheral graft infections, sensitivity, specificity and accuracy were 100%, Conclusion: The white blood cell scan seems a reliable diagnostic method for early diagnosis of PVGI, and it is more useful in aortofemoral graft infections.

Clinical usefulness of technetium-99m-HMPAO-labeled leukocyte scan in prosthetic vascular graft infection / Liberatore, Mauro; A. P., Iurilli; F., Ponzio; D., Prosperi; Santini, Claudio; Baiocchi, Pia; P., Serra; Rizzo, Luigi; Speziale, Francesco; Fiorani, Paolo; A., Centi Colella. - In: THE JOURNAL OF NUCLEAR MEDICINE. - ISSN 0161-5505. - 39:5(1998), pp. 875-879.

Clinical usefulness of technetium-99m-HMPAO-labeled leukocyte scan in prosthetic vascular graft infection.

LIBERATORE, Mauro;SANTINI, Claudio;BAIOCCHI, Pia;RIZZO, Luigi;SPEZIALE, Francesco;FIORANI, Paolo;
1998

Abstract

The infection of a prosthetic vascular graft (PVGI), although rare, is the most severe complication in reconstructive vascular surgery. The early diagnosis of this complication reduces the death rate from surgery. Aortofemoral graft infections differ clinically from peripheral graft infections in significant ways. The aim of this article is to evaluate separately the reliability of the Tc-99m-HMPAO-labeled leukocyte scan or white blood cell count (WBC) in the early detection of both aortofemoral and peripheral graft infections. Methods: One hundred sixty-two WBCs were performed on 129 consecutive patients with suspected aortofemoral (122 scans) and peripheral (40 scans) graft infection and in a 12-patient control group. Patients with suspected PVGI were categorized into three groups on the basis of their signs and symptoms on readmission: (a) patients with specific signs of graft infection (Group A); (b) patients with nonspecific signs of graft infection (Group B); and (c) patients with anastomotic aneurysms (Group C), Gram's stains of the perigraft exudate and graft cultures were performed and used as the gold standard in patients who underwent surgery. An 18-mo clinical follow-up was done to assess the presence or absence of graft infection in patients who did not have surgery. Results: In patients with suspected aortofemoral graft infections, the overall sensitivity, specificity and accuracy of WBCs (Groups A, B, C) were 100%, 92.5% and 97.5%, respectively, whereas sensitivity, specificity and accuracy calculated in the patients with nonspecific signs of graft infection (Groups B, C) were 100%, 92.3% and 96.9%, respectively. In patients with suspected peripheral graft infections, sensitivity, specificity and accuracy were 100%, Conclusion: The white blood cell scan seems a reliable diagnostic method for early diagnosis of PVGI, and it is more useful in aortofemoral graft infections.
1998
leukocyte scan; infection; technetium-99m-hmpao-labeled; vascular graft
01 Pubblicazione su rivista::01a Articolo in rivista
Clinical usefulness of technetium-99m-HMPAO-labeled leukocyte scan in prosthetic vascular graft infection / Liberatore, Mauro; A. P., Iurilli; F., Ponzio; D., Prosperi; Santini, Claudio; Baiocchi, Pia; P., Serra; Rizzo, Luigi; Speziale, Francesco; Fiorani, Paolo; A., Centi Colella. - In: THE JOURNAL OF NUCLEAR MEDICINE. - ISSN 0161-5505. - 39:5(1998), pp. 875-879.
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/247760
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 5
  • Scopus 73
  • ???jsp.display-item.citation.isi??? 62
social impact