The method developed to evaluate the hemocompatibility of artificial materials involves the determination of thromboxane production during the clotting of rabbit blood, in test tubes of different materials. The concentration of serum TXB2 obtained after incubation of whole blood in glass test tubes, for 40 min at 37 degrees C, averaged 416.8 +/- 23.3 ng/ml (mean +/- SE). Polymethylpentene, recognised as having a relatively poor blood compatibility, elicited 309.5 +/- 17.2 ng/ml of serum TXB2, while silicone and Avcothane, considered of better hemocompatibility, showed thromboxane levels of 276.2 +/- 28.2 and 222.9 +/- 31.5 ng/ml, respectively. These values validate the usefulness of the proposed method as a preliminary in vitro screening test of artificial materials intended for biomedical application.
A native whole blood test for the evaluation of blood surface interaction: determination of thromboxane production / Mantovani, E; Marconi, W; Cebo, B; Togna, Anna Rita; Togna, Giuseppina Ines; Caprino, Luciano. - In: INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS. - ISSN 0391-3988. - STAMPA. - 7:(1984), pp. 147-150.
A native whole blood test for the evaluation of blood surface interaction: determination of thromboxane production
TOGNA, Anna Rita;TOGNA, Giuseppina Ines;CAPRINO, Luciano
1984
Abstract
The method developed to evaluate the hemocompatibility of artificial materials involves the determination of thromboxane production during the clotting of rabbit blood, in test tubes of different materials. The concentration of serum TXB2 obtained after incubation of whole blood in glass test tubes, for 40 min at 37 degrees C, averaged 416.8 +/- 23.3 ng/ml (mean +/- SE). Polymethylpentene, recognised as having a relatively poor blood compatibility, elicited 309.5 +/- 17.2 ng/ml of serum TXB2, while silicone and Avcothane, considered of better hemocompatibility, showed thromboxane levels of 276.2 +/- 28.2 and 222.9 +/- 31.5 ng/ml, respectively. These values validate the usefulness of the proposed method as a preliminary in vitro screening test of artificial materials intended for biomedical application.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.