The NESTOR detector, at present under construction, is a telescope for high-energy neutrino astronomy. The apparatus, based on Cherenkov light detection, will be deployed in deep sea (about 4000m) near the S.W. Greek coast. We briefly describe the NESTOR detector, then we describe with more details the electronics for NESTOR data acquisition and transmission. The detector signals are sampled at 200MHz and all the resulting information are transmitted to the laboratory on 30km long electro-optical cable. The estimated Mean Time Between Failure of the full electronics system is greater than 20 years. Tests performed on the first prototypes confirm the main characteristics of these electronics: the dynamic range allowed for the signals is bigger than 1000, the pulse shape is reconstructed with an 8 bit ADC accuracy and the resolution in the measurement of the signal "threshold crossing time" is better than 200ps.

Data acquisition electronics for NESTOR experiment: Project and tests / Fabrizio, Ameli; Bonori, Maurizio; Sergio, Bottai; Capone, Antonio; S., Curti; Paolo, Desiati; G., De Marchis; Fabrizio, Massa; Masullo, Rocco; Luigi, Piccari; Italo, Vannucci. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 423:1(1999), pp. 146-156. [10.1016/s0168-9002(98)00921-8]

Data acquisition electronics for NESTOR experiment: Project and tests

BONORI, Maurizio;CAPONE, Antonio;MASULLO, Rocco;
1999

Abstract

The NESTOR detector, at present under construction, is a telescope for high-energy neutrino astronomy. The apparatus, based on Cherenkov light detection, will be deployed in deep sea (about 4000m) near the S.W. Greek coast. We briefly describe the NESTOR detector, then we describe with more details the electronics for NESTOR data acquisition and transmission. The detector signals are sampled at 200MHz and all the resulting information are transmitted to the laboratory on 30km long electro-optical cable. The estimated Mean Time Between Failure of the full electronics system is greater than 20 years. Tests performed on the first prototypes confirm the main characteristics of these electronics: the dynamic range allowed for the signals is bigger than 1000, the pulse shape is reconstructed with an 8 bit ADC accuracy and the resolution in the measurement of the signal "threshold crossing time" is better than 200ps.
1999
01 Pubblicazione su rivista::01a Articolo in rivista
Data acquisition electronics for NESTOR experiment: Project and tests / Fabrizio, Ameli; Bonori, Maurizio; Sergio, Bottai; Capone, Antonio; S., Curti; Paolo, Desiati; G., De Marchis; Fabrizio, Massa; Masullo, Rocco; Luigi, Piccari; Italo, Vannucci. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 423:1(1999), pp. 146-156. [10.1016/s0168-9002(98)00921-8]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/247410
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 8
  • ???jsp.display-item.citation.isi??? 8
social impact