A series of dynamic snap-back tests were carried out on a residence building in southern Italy at Rapolla (Potenza-Basilicata). The aim of the research was to investigate the seismic behaviour of low-rise base isolated structures mounted on rubber bearings only, or with a hybrid isolation system (sliding bearings for isolation and steel rubber bearings to have a re-centring force). High initial displacements (up to 170 mm) were reached using a reusable mechanical device, and a 200 t reaction wall. The paper presents the experimental study performed and its main results. As far as the protection level is concerned, the experimental response of the structure on the hybrid isolation system and on the steel rubber isolation system has been compared with the code seismic actions confirming the effectiveness of both tested isolation systems. (C) 2004 Elsevier Ltd. All rights reserved.

Field testing of low-rise base isolated building / Braga, Franco; Michelangelo, Laterza. - In: ENGINEERING STRUCTURES. - ISSN 0141-0296. - STAMPA. - 26:11(2004), pp. 1599-1610. [10.1016/j.engstruct.2004.06.002]

Field testing of low-rise base isolated building

BRAGA, Franco;
2004

Abstract

A series of dynamic snap-back tests were carried out on a residence building in southern Italy at Rapolla (Potenza-Basilicata). The aim of the research was to investigate the seismic behaviour of low-rise base isolated structures mounted on rubber bearings only, or with a hybrid isolation system (sliding bearings for isolation and steel rubber bearings to have a re-centring force). High initial displacements (up to 170 mm) were reached using a reusable mechanical device, and a 200 t reaction wall. The paper presents the experimental study performed and its main results. As far as the protection level is concerned, the experimental response of the structure on the hybrid isolation system and on the steel rubber isolation system has been compared with the code seismic actions confirming the effectiveness of both tested isolation systems. (C) 2004 Elsevier Ltd. All rights reserved.
2004
base isolation; elastomeric bearings; free vibration; full-scale experimental tests; reaction wall; seismic isolation; sliding bearings
01 Pubblicazione su rivista::01a Articolo in rivista
Field testing of low-rise base isolated building / Braga, Franco; Michelangelo, Laterza. - In: ENGINEERING STRUCTURES. - ISSN 0141-0296. - STAMPA. - 26:11(2004), pp. 1599-1610. [10.1016/j.engstruct.2004.06.002]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/24651
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 43
  • ???jsp.display-item.citation.isi??? 33
social impact