The construction of the KLOE lead-scintillating fibres electromagnetic calorimeter has been completed. The final results of the extensive quality checks of all the calorimeter modules are presented here. The measurements have been done in the Frascati Laboratories at a cosmic ray test facility using minimum ionizing particles. The results show that all the calorimeter modules are well fulfilling the design specifications concerning time and energy resolutions. Furthermore, by using the same cosmic ray facility, all the calorimeter elements have been also pre-calibrated.

Quality checks and first calibration of the KLOE electromagnetic calorimeter / M., Antonelli; G., Barbiellini; S., Bertolucci; Bini, Cesare; C., Bloise; G., Cabibbo; Caloi, Rita; P., Campana; F., Cervelli; DE ZORZI, Guido; G., Di Cosimo; DI DOMENICO, Antonio; S., Di Falco; O., Erriquez; A., Farilla; A., Ferrari; Franzini, Paolo; A., Galli; Gauzzi, Paolo; S., Giovannella; E., Graziani; H. Q., Han; S. W., Han; M., Incagli; W., Kim; G., Lanfranchi; J., Lee Franzini; T., Lomtadze; I., Minashvili; S., Miscetti; F., Murtas; A., Passeri; F., Scuri; E., Spiriti; L., Tortora; G., Venanzoni; Y. G., Xie; J. Q., Zhang. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 409:1-3(1998), pp. 558-560. [10.1016/s0168-9002(97)01317-x]

Quality checks and first calibration of the KLOE electromagnetic calorimeter

BINI, Cesare;CALOI, Rita;DE ZORZI, Guido;DI DOMENICO, Antonio;FRANZINI, Paolo;GAUZZI, Paolo;
1998

Abstract

The construction of the KLOE lead-scintillating fibres electromagnetic calorimeter has been completed. The final results of the extensive quality checks of all the calorimeter modules are presented here. The measurements have been done in the Frascati Laboratories at a cosmic ray test facility using minimum ionizing particles. The results show that all the calorimeter modules are well fulfilling the design specifications concerning time and energy resolutions. Furthermore, by using the same cosmic ray facility, all the calorimeter elements have been also pre-calibrated.
1998
01 Pubblicazione su rivista::01a Articolo in rivista
Quality checks and first calibration of the KLOE electromagnetic calorimeter / M., Antonelli; G., Barbiellini; S., Bertolucci; Bini, Cesare; C., Bloise; G., Cabibbo; Caloi, Rita; P., Campana; F., Cervelli; DE ZORZI, Guido; G., Di Cosimo; DI DOMENICO, Antonio; S., Di Falco; O., Erriquez; A., Farilla; A., Ferrari; Franzini, Paolo; A., Galli; Gauzzi, Paolo; S., Giovannella; E., Graziani; H. Q., Han; S. W., Han; M., Incagli; W., Kim; G., Lanfranchi; J., Lee Franzini; T., Lomtadze; I., Minashvili; S., Miscetti; F., Murtas; A., Passeri; F., Scuri; E., Spiriti; L., Tortora; G., Venanzoni; Y. G., Xie; J. Q., Zhang. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 409:1-3(1998), pp. 558-560. [10.1016/s0168-9002(97)01317-x]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/245200
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 4
social impact