To assess the diagnostic accuracy of the combination of a biophysical (lamellar body count [LB]) with a biochemical test lecithin/sphingomyelin ratio (L/S) for the evaluation of fetal lung maturity (FLM) in cases of intermediate-borderline pulmonary maturity. We studied 105 cases with one or both intermediate (2.1-2.4:1 for L/S and/or 15,000-19,000/microL for LB) or borderline (2.5:1 for L/S and/or 20,000/microL for LB count) FLM indices and no phosphatidylglycerol who delivered within 72 hours of amniocentesis, excluding multiple gestation and contaminated amniotic fluid samples. The biophysical x biochemical marker (B x B) was calculated by multiplying L/S by the corresponding LB, then dividing by 10(3). By using the ROC curve, a cutoff of 50 was found. B x B values were lower in respiratory distress syndrome (RDS) than in the non-RDS group (30 [23-41] vs. 52 [50-70], P < .001; median, 25-75%). All RDS cases had a B x B value < 50. Diagnostic accuracy for B x B was: sensitivity, 100%; specificity, 83%; positive predictive value, 61%; negative predictive value, 100%. Sensitivity and positive predictive values were higher for B x B than L/S. B x B may be a useful tool for cases with borderline FLM.
The biophysical/biochemical test. A new marker of fetal lung maturity in borderline cases / J. j., Piazze; Anceschi, Maurizio Marco; L., Maranghi; Porpora, Maria Grazia; Cosmi, Ermelando. - In: JOURNAL OF REPRODUCTIVE MEDICINE. - ISSN 0024-7758. - STAMPA. - 44:7(1999), pp. 611-615.
The biophysical/biochemical test. A new marker of fetal lung maturity in borderline cases.
ANCESCHI, Maurizio Marco;PORPORA, Maria Grazia;COSMI, Ermelando
1999
Abstract
To assess the diagnostic accuracy of the combination of a biophysical (lamellar body count [LB]) with a biochemical test lecithin/sphingomyelin ratio (L/S) for the evaluation of fetal lung maturity (FLM) in cases of intermediate-borderline pulmonary maturity. We studied 105 cases with one or both intermediate (2.1-2.4:1 for L/S and/or 15,000-19,000/microL for LB) or borderline (2.5:1 for L/S and/or 20,000/microL for LB count) FLM indices and no phosphatidylglycerol who delivered within 72 hours of amniocentesis, excluding multiple gestation and contaminated amniotic fluid samples. The biophysical x biochemical marker (B x B) was calculated by multiplying L/S by the corresponding LB, then dividing by 10(3). By using the ROC curve, a cutoff of 50 was found. B x B values were lower in respiratory distress syndrome (RDS) than in the non-RDS group (30 [23-41] vs. 52 [50-70], P < .001; median, 25-75%). All RDS cases had a B x B value < 50. Diagnostic accuracy for B x B was: sensitivity, 100%; specificity, 83%; positive predictive value, 61%; negative predictive value, 100%. Sensitivity and positive predictive values were higher for B x B than L/S. B x B may be a useful tool for cases with borderline FLM.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.