Gamma ray imaging is usually accomplished by the use of a relatively large scintillating crystal coupled to either a number of photomultipliers (PMTs) (Anger Camera) or to a single large Position Sensitive PMT (PSPMT). Recently the development of new diagnostic techniques, such as scintimammography and radio-guided surgery, have highlighted a number of significant limitations of the Anger camera in such imaging procedures. In this paper a dedicated gamma camera is proposed for clinical applications with the aim of improving image quality by utilizing detectors with an appropriate size and shape for the part of the body under examination. This novel scintillation camera is based upon an array of PSPMTs (Hamamatsu R5900-C8). The basic concept of this camera is identical to the Anger Camera with the exception of the substitution of PSPMTs for the PMTs. In this configuration it is possible to use the high resolution of the PSPMTs and still correctly position events lying between PSPMTs. In this work the test configuration is a 2 by 2 array of PSPMTs. Some advantages of this camera are: spatial resolution less than 2 mm FWHM, good linearity, thickness less than 3 cm, light weight, lower cost than equivalent area PSPMT, large detection area when coupled to scintillating arrays, small dead boundary zone (<3 mm) and flexibility in the shape of the camera.

Multi-PSPMT scintillation camera / Pani, Roberto; A., Soluri; A., Pergola; Pellegrini, Rosanna; R., Scaf; DE VINCENTIS, Giuseppe; G., Trotta; Scopinaro, Francesco. - In: IEEE TRANSACTIONS ON NUCLEAR SCIENCE. - ISSN 0018-9499. - STAMPA. - 46:3 PART 2(1999), pp. 702-708. (Intervento presentato al convegno 1998 Medical Imaging Conference tenutosi a TORONTO, CANADA nel NOV 12-14, 1998) [10.1109/23.775602].

Multi-PSPMT scintillation camera

PANI, Roberto;PELLEGRINI, Rosanna;DE VINCENTIS, Giuseppe;SCOPINARO, Francesco
1999

Abstract

Gamma ray imaging is usually accomplished by the use of a relatively large scintillating crystal coupled to either a number of photomultipliers (PMTs) (Anger Camera) or to a single large Position Sensitive PMT (PSPMT). Recently the development of new diagnostic techniques, such as scintimammography and radio-guided surgery, have highlighted a number of significant limitations of the Anger camera in such imaging procedures. In this paper a dedicated gamma camera is proposed for clinical applications with the aim of improving image quality by utilizing detectors with an appropriate size and shape for the part of the body under examination. This novel scintillation camera is based upon an array of PSPMTs (Hamamatsu R5900-C8). The basic concept of this camera is identical to the Anger Camera with the exception of the substitution of PSPMTs for the PMTs. In this configuration it is possible to use the high resolution of the PSPMTs and still correctly position events lying between PSPMTs. In this work the test configuration is a 2 by 2 array of PSPMTs. Some advantages of this camera are: spatial resolution less than 2 mm FWHM, good linearity, thickness less than 3 cm, light weight, lower cost than equivalent area PSPMT, large detection area when coupled to scintillating arrays, small dead boundary zone (<3 mm) and flexibility in the shape of the camera.
1999
1998 Medical Imaging Conference
04 Pubblicazione in atti di convegno::04d Abstract in atti di convegno
Multi-PSPMT scintillation camera / Pani, Roberto; A., Soluri; A., Pergola; Pellegrini, Rosanna; R., Scaf; DE VINCENTIS, Giuseppe; G., Trotta; Scopinaro, Francesco. - In: IEEE TRANSACTIONS ON NUCLEAR SCIENCE. - ISSN 0018-9499. - STAMPA. - 46:3 PART 2(1999), pp. 702-708. (Intervento presentato al convegno 1998 Medical Imaging Conference tenutosi a TORONTO, CANADA nel NOV 12-14, 1998) [10.1109/23.775602].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/242549
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 16
  • ???jsp.display-item.citation.isi??? 67
social impact