PURPOSE: To determine learning effect in healthy patients without perimetric experience, tested with the frequency doubling technology perimetry, with the new model Matrix. PATIENTS AND METHODS: Frequency doubling technology in the 30-2 threshold mode was performed on 37 healthy subjects. Each subject was tested twice in different sessions. The test always began with the right eye (RE) and continued with the left eye (LE). To evaluate learning effect the results of the REs at the first session were compared with those of the LE. The following parameters were evaluated: foveal threshold (FT), reliability indexes, mean defect (MD), pattern standard deviation (PSD), glaucoma hemifield test (GHT), duration of examination. RESULTS: At the first session the average values of RE were FT=30.81 db, MD=-1 db, PSD=3.01 db, and duration of the examination=383.27 "and of LE were FT=30.73, MD=-0.79 db, PSD=2.97 db, and duration of examination 382.62." At the second session the average values of RE were FT=32.22 db, MD=+0.16 db, PSD 2.75 db, and duration of examination=374.97 db. The reliability was different and the GHT between the RE and LE in the first and second session was also different. CONCLUSIONS: A learning effect was observed between the first and the second sessions and the results of the GHT appeared improved. This above all should be taken into account when considering the clinical use of this test to avoid erroneous diagnostic conclusions. © 2007 Lippincott Williams & Wilkins, Inc.

The influence of learning effect on frequency doubling technology perimetry (Matrix) / Contestabile, Maria Teresa; Andrea, Perdicchi; Stefano, Amodeo; Vincenzo, Recupero; Recupero, Santi Maria. - In: JOURNAL OF GLAUCOMA. - ISSN 1057-0829. - 16:3(2007), pp. 297-301. [10.1097/ijg.0b013e31803919ed]

The influence of learning effect on frequency doubling technology perimetry (Matrix)

CONTESTABILE, Maria Teresa;RECUPERO, Santi Maria
2007

Abstract

PURPOSE: To determine learning effect in healthy patients without perimetric experience, tested with the frequency doubling technology perimetry, with the new model Matrix. PATIENTS AND METHODS: Frequency doubling technology in the 30-2 threshold mode was performed on 37 healthy subjects. Each subject was tested twice in different sessions. The test always began with the right eye (RE) and continued with the left eye (LE). To evaluate learning effect the results of the REs at the first session were compared with those of the LE. The following parameters were evaluated: foveal threshold (FT), reliability indexes, mean defect (MD), pattern standard deviation (PSD), glaucoma hemifield test (GHT), duration of examination. RESULTS: At the first session the average values of RE were FT=30.81 db, MD=-1 db, PSD=3.01 db, and duration of the examination=383.27 "and of LE were FT=30.73, MD=-0.79 db, PSD=2.97 db, and duration of examination 382.62." At the second session the average values of RE were FT=32.22 db, MD=+0.16 db, PSD 2.75 db, and duration of examination=374.97 db. The reliability was different and the GHT between the RE and LE in the first and second session was also different. CONCLUSIONS: A learning effect was observed between the first and the second sessions and the results of the GHT appeared improved. This above all should be taken into account when considering the clinical use of this test to avoid erroneous diagnostic conclusions. © 2007 Lippincott Williams & Wilkins, Inc.
2007
frequency doubling technology; learning effect; perimetry
01 Pubblicazione su rivista::01a Articolo in rivista
The influence of learning effect on frequency doubling technology perimetry (Matrix) / Contestabile, Maria Teresa; Andrea, Perdicchi; Stefano, Amodeo; Vincenzo, Recupero; Recupero, Santi Maria. - In: JOURNAL OF GLAUCOMA. - ISSN 1057-0829. - 16:3(2007), pp. 297-301. [10.1097/ijg.0b013e31803919ed]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/239267
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 6
  • Scopus 19
  • ???jsp.display-item.citation.isi??? 19
social impact