PURPOSE: To compare multi-detector row spiral computed tomographic (CT) angiography with digital subtraction angiography (DSA) in evaluation of the infrarenal aorta and lower-extremity arterial system. MATERIALS AND METHODS: Fifty patients with peripheral arterial occlusive disease were evaluated with multi-detector row CT angiography and DSA. Arteries depicted at CT angiography and DSA were graded separately for degree of stenosis as 23 anatomic segments (infrarenal aorta, right and left common iliac artery, internal iliac artery, external iliac artery, common femoral artery, superficial femoral artery, deep femoral artery, popliteal artery, anterior tibial artery, tibioperoneal trunk, posterior tibial artery, and peroneal artery). Grades included the following: 1, normal patency; 2, moderate (< or =50%) stenosis; 3, focal severe (>50%) stenosis; 4, multiple severe stenoses; and 5, occlusion. Three readers independently interpreted the images, and statistical analysis was performed. The results of image interpretation were evaluated for strength of agreement by using Cohen kappa statistics. On the basis of consensus readings, sensitivity, specificity, and accuracy for detection of stenotic lesions were calculated, with findings at DSA used as the reference standard. RESULTS: Substantial to almost perfect interobserver agreement was achieved in all cases. At DSA, 349 diseased segments were found among the 1,137 segments evaluated. Sensitivity, specificity, and accuracy, based on a consensus reading of multi-detector row CT angiograms, were 96%, 93%, and 94%, respectively. A statistically significant difference (P <.05) between DSA and multi-detector row CT angiography was present only in arteries graded 1 or 2. Interobserver agreement was almost perfect among the three readers for treatment recommendations based on findings at CT angiography and DSA. CONCLUSION: Multi-detector row CT angiography appears consistent and accurate in the assessment of patients with peripheral arterial occlusive disease.

Infrarenal aortic and lower-extremity arterial disease: diagnostic performance of multi-detector row CT angiography / Catalano, Carlo; Fraioli, F; Laghi, Andrea; Napoli, Alessandro; Bezzi, Mario; Pediconi, Federica; Danti, M; Nofroni, Italo; Passariello, Roberto. - In: RADIOLOGY. - ISSN 0033-8419. - STAMPA. - May;231(2):(2004), pp. 555-563. [10.1148/radiol.2312020920]

Infrarenal aortic and lower-extremity arterial disease: diagnostic performance of multi-detector row CT angiography.

CATALANO, Carlo;LAGHI, ANDREA;NAPOLI, ALESSANDRO;BEZZI, Mario;PEDICONI, FEDERICA;NOFRONI, Italo;PASSARIELLO, Roberto
2004

Abstract

PURPOSE: To compare multi-detector row spiral computed tomographic (CT) angiography with digital subtraction angiography (DSA) in evaluation of the infrarenal aorta and lower-extremity arterial system. MATERIALS AND METHODS: Fifty patients with peripheral arterial occlusive disease were evaluated with multi-detector row CT angiography and DSA. Arteries depicted at CT angiography and DSA were graded separately for degree of stenosis as 23 anatomic segments (infrarenal aorta, right and left common iliac artery, internal iliac artery, external iliac artery, common femoral artery, superficial femoral artery, deep femoral artery, popliteal artery, anterior tibial artery, tibioperoneal trunk, posterior tibial artery, and peroneal artery). Grades included the following: 1, normal patency; 2, moderate (< or =50%) stenosis; 3, focal severe (>50%) stenosis; 4, multiple severe stenoses; and 5, occlusion. Three readers independently interpreted the images, and statistical analysis was performed. The results of image interpretation were evaluated for strength of agreement by using Cohen kappa statistics. On the basis of consensus readings, sensitivity, specificity, and accuracy for detection of stenotic lesions were calculated, with findings at DSA used as the reference standard. RESULTS: Substantial to almost perfect interobserver agreement was achieved in all cases. At DSA, 349 diseased segments were found among the 1,137 segments evaluated. Sensitivity, specificity, and accuracy, based on a consensus reading of multi-detector row CT angiograms, were 96%, 93%, and 94%, respectively. A statistically significant difference (P <.05) between DSA and multi-detector row CT angiography was present only in arteries graded 1 or 2. Interobserver agreement was almost perfect among the three readers for treatment recommendations based on findings at CT angiography and DSA. CONCLUSION: Multi-detector row CT angiography appears consistent and accurate in the assessment of patients with peripheral arterial occlusive disease.
2004
Computed tomography; Angiography; atherosclerosis
01 Pubblicazione su rivista::01a Articolo in rivista
Infrarenal aortic and lower-extremity arterial disease: diagnostic performance of multi-detector row CT angiography / Catalano, Carlo; Fraioli, F; Laghi, Andrea; Napoli, Alessandro; Bezzi, Mario; Pediconi, Federica; Danti, M; Nofroni, Italo; Passariello, Roberto. - In: RADIOLOGY. - ISSN 0033-8419. - STAMPA. - May;231(2):(2004), pp. 555-563. [10.1148/radiol.2312020920]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/239165
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 16
  • Scopus 203
  • ???jsp.display-item.citation.isi??? 149
social impact