The paper deals with the shunt compensation of long cable and mixed overhead-cable EHV transmission lines. Attention is focused on "siphon" mixed lines (MLs) including long cable stretches. Shunt compensation requirements of such lines, based on steady-state operational constraints such as voltage jump at the supply node, open-end overvoltages and capacitive rating of line circuit breakers, are evaluated. Alternative locations of shunt reactors (SRs) at the cable stretch terminals or at the ML terminals are discussed and simple calculation procedures are proposed for both configurations. Numerical examples, based on planned or prospective long 400 kV-50 Hz cable applications in Italy, are presented.

Shunt compensation of EHV cables and mixed overhead-cable lines / Lauria, Stefano; Gatta, Fabio Massimo; Luigi, Colla. - (2007), pp. 1344-1349. (Intervento presentato al convegno IEEE Lausanne Powertech tenutosi a Lausanne, SWITZERLAND nel JUL 01-05, 2007) [10.1109/pct.2007.4538511].

Shunt compensation of EHV cables and mixed overhead-cable lines

LAURIA, Stefano;GATTA, Fabio Massimo;
2007

Abstract

The paper deals with the shunt compensation of long cable and mixed overhead-cable EHV transmission lines. Attention is focused on "siphon" mixed lines (MLs) including long cable stretches. Shunt compensation requirements of such lines, based on steady-state operational constraints such as voltage jump at the supply node, open-end overvoltages and capacitive rating of line circuit breakers, are evaluated. Alternative locations of shunt reactors (SRs) at the cable stretch terminals or at the ML terminals are discussed and simple calculation procedures are proposed for both configurations. Numerical examples, based on planned or prospective long 400 kV-50 Hz cable applications in Italy, are presented.
2007
IEEE Lausanne Powertech
capacitive switching; ehv cables; mixed lines; shunt compensation; temporary overvoltages
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Shunt compensation of EHV cables and mixed overhead-cable lines / Lauria, Stefano; Gatta, Fabio Massimo; Luigi, Colla. - (2007), pp. 1344-1349. (Intervento presentato al convegno IEEE Lausanne Powertech tenutosi a Lausanne, SWITZERLAND nel JUL 01-05, 2007) [10.1109/pct.2007.4538511].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/238624
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 31
  • ???jsp.display-item.citation.isi??? 5
social impact