Since 1997, our group of Physics together with Nuclear Physicians studies imaging probes (IP), hand-held, high-resolution gamma cameras for radio-guided surgery (RGS). Present work is aimed to verify the usefulness of two updated IP in different surgical operations. Forty patients scheduled for breast cancer sentinel node (SN) biopsy, five patients with nodal recurrence of thyroid cancer, seven patients with parathyroid adenomas, five patients with neuroendocrine tumours (NET), were operated under the guide of IP. We 2 used two different IP with field of view of 1 and 4in.(2), respectively and intrinsic spatial resolution of about 2mm. Radioisotopes were (99m)Tc, (123)I and (111)In. The 1 in.(2) IP detected SN in all the 40 patients and more than one node in 24, whereas anger camera (AC) failed locating SN in four patients and detected true positive second nodes in only nine patients. The 4 in.(2) IP was used for RGS of thyroid, parathyroid and NETs. It detected eight latero-cervical nodes. In the same patients, AC detected five invaded nodes. Parathyroid adenomas detected by IP were 10 in 7 patients, NET five in five patients. One and 4 in.(2) IPs showed usefulness in all operations. Initial studies on SN biopsy were carried out on small series of patients to validate IP and to demonstrate the effectiveness and usefulness of IP alone or against conventional probes. We propose the use of the IP as control method for legal documentation and surgeon strategy guide before and after lesion(s) removal. (c) 2007 Elsevier B.V. All rights reserved.

Radioisotope guided surgery with imaging probe, a hand-held high-resolution gamma camera / Soluri, Alessandro; Trotta, Carlo; Scopinaro, Francesco; A., Tofani; C., D'Alessandria; Pasta, Vittorio; Stella, Salvatore; Riccardo, Massari. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 583:2-3(2007), pp. 366-371. [10.1016/j.nima.2007.09.031]

Radioisotope guided surgery with imaging probe, a hand-held high-resolution gamma camera

SOLURI, Alessandro;TROTTA, carlo;SCOPINARO, Francesco;PASTA, Vittorio;STELLA, Salvatore;
2007

Abstract

Since 1997, our group of Physics together with Nuclear Physicians studies imaging probes (IP), hand-held, high-resolution gamma cameras for radio-guided surgery (RGS). Present work is aimed to verify the usefulness of two updated IP in different surgical operations. Forty patients scheduled for breast cancer sentinel node (SN) biopsy, five patients with nodal recurrence of thyroid cancer, seven patients with parathyroid adenomas, five patients with neuroendocrine tumours (NET), were operated under the guide of IP. We 2 used two different IP with field of view of 1 and 4in.(2), respectively and intrinsic spatial resolution of about 2mm. Radioisotopes were (99m)Tc, (123)I and (111)In. The 1 in.(2) IP detected SN in all the 40 patients and more than one node in 24, whereas anger camera (AC) failed locating SN in four patients and detected true positive second nodes in only nine patients. The 4 in.(2) IP was used for RGS of thyroid, parathyroid and NETs. It detected eight latero-cervical nodes. In the same patients, AC detected five invaded nodes. Parathyroid adenomas detected by IP were 10 in 7 patients, NET five in five patients. One and 4 in.(2) IPs showed usefulness in all operations. Initial studies on SN biopsy were carried out on small series of patients to validate IP and to demonstrate the effectiveness and usefulness of IP alone or against conventional probes. We propose the use of the IP as control method for legal documentation and surgeon strategy guide before and after lesion(s) removal. (c) 2007 Elsevier B.V. All rights reserved.
2007
portable gamma camera; position-sensitive photomultiplier tube; gamma ray imager; scintillation detector
01 Pubblicazione su rivista::01a Articolo in rivista
Radioisotope guided surgery with imaging probe, a hand-held high-resolution gamma camera / Soluri, Alessandro; Trotta, Carlo; Scopinaro, Francesco; A., Tofani; C., D'Alessandria; Pasta, Vittorio; Stella, Salvatore; Riccardo, Massari. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 583:2-3(2007), pp. 366-371. [10.1016/j.nima.2007.09.031]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/238562
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 14
  • ???jsp.display-item.citation.isi??? 12
social impact