Tracheopulmonary intubation is the most common misplacement site for narrow-bore feeding tube and it might be associated with severe pleuro-pulmonary complications. A 38-year-old female with a severe bilateral pneumonia and acute respiratory insufficiency was admitted in the ICU, intubated, and mechanically ventilated. Few hours after the insertion of a narrow-bore feeding tube the patient's oxygen saturation dropped with hypotension and tachycardia. A large left-side hydropneurnothorax developed requiring a chest tube. Air-leakage was important and bronchoscopic implant of one-way endobronchial valve was accomplished. Immediate and substantial decrease of air-leakage was observed, and it completely stopped after 5 days; as soon as the patient was extubated. Endobrochial one-way valve, specifically designed for bronchoscopic lung volume reduction, resulted in being safe and effective to control a significant and prolonged air-leakage due to a malposition of a narrow-bore feeding tube. (c) 2006 Elsevier B.V. All rights reserved.

Successful treatment with one-way endobronchial valve of large air-leakage complicating narrow-bore enteral feeding tube malposition / DE GIACOMO, Tiziano; Venuta, Federico; Diso, Daniele; Coloni, Giorgio Furio. - In: EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY. - ISSN 1010-7940. - STAMPA. - 30:5(2006), pp. 811-812. [10.1016/j.ejcts.2006.08.005]

Successful treatment with one-way endobronchial valve of large air-leakage complicating narrow-bore enteral feeding tube malposition

DE GIACOMO, Tiziano;VENUTA, Federico;DISO, DANIELE;COLONI, Giorgio Furio
2006

Abstract

Tracheopulmonary intubation is the most common misplacement site for narrow-bore feeding tube and it might be associated with severe pleuro-pulmonary complications. A 38-year-old female with a severe bilateral pneumonia and acute respiratory insufficiency was admitted in the ICU, intubated, and mechanically ventilated. Few hours after the insertion of a narrow-bore feeding tube the patient's oxygen saturation dropped with hypotension and tachycardia. A large left-side hydropneurnothorax developed requiring a chest tube. Air-leakage was important and bronchoscopic implant of one-way endobronchial valve was accomplished. Immediate and substantial decrease of air-leakage was observed, and it completely stopped after 5 days; as soon as the patient was extubated. Endobrochial one-way valve, specifically designed for bronchoscopic lung volume reduction, resulted in being safe and effective to control a significant and prolonged air-leakage due to a malposition of a narrow-bore feeding tube. (c) 2006 Elsevier B.V. All rights reserved.
2006
bronchoscopy; nutrition; pneumothorax
01 Pubblicazione su rivista::01a Articolo in rivista
Successful treatment with one-way endobronchial valve of large air-leakage complicating narrow-bore enteral feeding tube malposition / DE GIACOMO, Tiziano; Venuta, Federico; Diso, Daniele; Coloni, Giorgio Furio. - In: EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY. - ISSN 1010-7940. - STAMPA. - 30:5(2006), pp. 811-812. [10.1016/j.ejcts.2006.08.005]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/234832
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 4
  • Scopus 18
  • ???jsp.display-item.citation.isi??? 12
social impact