In order to produce a high brightness electron beam for the Frascati Linac coherent light source (SPARC) the use of an accelerating section with frequency equal to the fourth harmonic of the main S-Band Linac frequency is needed. This paper discusses the design and the realization of a compact X-Band linear accelerating section for obtaining 5 MV average accelerating gradient, working at a frequency of 11.424 GHz and operating on the π/2 standing wave mode. Numerical predictions compared with measurements made on a copper prototype at room temperature are reported.
A bi-periodic X-Band cavity for SPARC / Spataro, B; Alesini, D; Bacci, A; Ficcadenti, L; Mostacci, Andrea; Palumbo, Luigi; Parodi, R.. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - STAMPA. - 586:2(2007), pp. 133-142. [10.1016/j.nima.2007.10.040]
A bi-periodic X-Band cavity for SPARC
FICCADENTI L;MOSTACCI, Andrea;PALUMBO, Luigi;
2007
Abstract
In order to produce a high brightness electron beam for the Frascati Linac coherent light source (SPARC) the use of an accelerating section with frequency equal to the fourth harmonic of the main S-Band Linac frequency is needed. This paper discusses the design and the realization of a compact X-Band linear accelerating section for obtaining 5 MV average accelerating gradient, working at a frequency of 11.424 GHz and operating on the π/2 standing wave mode. Numerical predictions compared with measurements made on a copper prototype at room temperature are reported.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.