The presence of long-period pulses in near-fault records can be considered as an important factor in causing damage due to the transmission of large amounts of energy to the structures in a very short time. Under such circumstances high-energy dissipation demands usually occur, which are likely to concentrate in the weakest parts of the structure. The maximum nonlinear response or collapse often happens at the onset of directivity pulse and fling, and this time is not predicted by the natural structural vibration periods. Nonlinear response leading to collapse may in most cases occur only during one large amplitude pulse of displacement. From the study of the response of both linear and nonlinear SDOF systems, the effects of these distinctive long-period pulses have been assessed by means of : (i) synthetic parameters directly derived from the strong ground motion records, and (ii) elastic and inelastic spectra of both conventional and energy-based seismic demand parameters. SDOF systems have first been subjected to records obtained during recent earthquakes in near-fault areas in forward directivity conditions. The results indicate that long duration pulses strongly affect the inelastic response, with very high energy and displacement demands which may be several times larger than the limit values specified by the majority of codes. In addition, from the recognition of the fundamental importance of velocity and energy-based parameters in the characterization of near-fault signals, idealized pulses equivalent to near-fault signals have been defined on account of such parameters. Equivalent pulses are capable of representing the salient observed features of the response to near-fault recorded ground motions.

Characterization of the dynamic response of structures to damaging pulse-type near-fault ground motions / Mollaioli, Fabrizio; Silvia, Bruno; Decanini, Luis Domingo; Giuliano F., Panza. - In: MECCANICA. - ISSN 0025-6455. - STAMPA. - 41:1(2006), pp. 23-46. [10.1007/s11012-005-7965-y]

Characterization of the dynamic response of structures to damaging pulse-type near-fault ground motions

MOLLAIOLI, Fabrizio;DECANINI, Luis Domingo;
2006

Abstract

The presence of long-period pulses in near-fault records can be considered as an important factor in causing damage due to the transmission of large amounts of energy to the structures in a very short time. Under such circumstances high-energy dissipation demands usually occur, which are likely to concentrate in the weakest parts of the structure. The maximum nonlinear response or collapse often happens at the onset of directivity pulse and fling, and this time is not predicted by the natural structural vibration periods. Nonlinear response leading to collapse may in most cases occur only during one large amplitude pulse of displacement. From the study of the response of both linear and nonlinear SDOF systems, the effects of these distinctive long-period pulses have been assessed by means of : (i) synthetic parameters directly derived from the strong ground motion records, and (ii) elastic and inelastic spectra of both conventional and energy-based seismic demand parameters. SDOF systems have first been subjected to records obtained during recent earthquakes in near-fault areas in forward directivity conditions. The results indicate that long duration pulses strongly affect the inelastic response, with very high energy and displacement demands which may be several times larger than the limit values specified by the majority of codes. In addition, from the recognition of the fundamental importance of velocity and energy-based parameters in the characterization of near-fault signals, idealized pulses equivalent to near-fault signals have been defined on account of such parameters. Equivalent pulses are capable of representing the salient observed features of the response to near-fault recorded ground motions.
2006
dynamics of structures; earthquake mechanics; response spectra; seismology; strong ground motion
01 Pubblicazione su rivista::01a Articolo in rivista
Characterization of the dynamic response of structures to damaging pulse-type near-fault ground motions / Mollaioli, Fabrizio; Silvia, Bruno; Decanini, Luis Domingo; Giuliano F., Panza. - In: MECCANICA. - ISSN 0025-6455. - STAMPA. - 41:1(2006), pp. 23-46. [10.1007/s11012-005-7965-y]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/234762
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 58
  • ???jsp.display-item.citation.isi??? 42
social impact