The first Barrel Inner Large chamber of the Monitored Drift Tube (MDT) tracking detector for the muon spectrometer of the ATLAS experiment has been tested with a high-energy muon beam. After a description of the MDT characteristics, we present the test beam experimental set-up, the data analysis techniques and discuss the results. The chamber was operated with a Ar(93%)-CO2(7%) gas mixture at 3-bar pressure. The performance studies include the chamber calibration, the single-tube resolution, efficiency and electronic noise, and their behaviour as a function of the high-voltage setting and discriminator threshold. (C) 2003 Elsevier B.V. All rights reserved.
Test of the first BIL tracking chamber for the ATLAS muon spectrometer / G., Avolio; Bagnaia, Paolo; A., Baroncelli; M., Beretta; Bini, Cesare; P., Branchini; M., Cirilli; M., Iodice; A., Lanza; L., La Rotonda; E., Meoni; D., Orestano; E., Pasqualucci; F., Petrucci; L., Pontecorvo. - In: NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH. SECTION A, ACCELERATORS, SPECTROMETERS, DETECTORS AND ASSOCIATED EQUIPMENT. - ISSN 0168-9002. - 523:3(2004), pp. 309-322. [10.1016/j.nima.2003.11.425]
Test of the first BIL tracking chamber for the ATLAS muon spectrometer
BAGNAIA, Paolo;BINI, Cesare;
2004
Abstract
The first Barrel Inner Large chamber of the Monitored Drift Tube (MDT) tracking detector for the muon spectrometer of the ATLAS experiment has been tested with a high-energy muon beam. After a description of the MDT characteristics, we present the test beam experimental set-up, the data analysis techniques and discuss the results. The chamber was operated with a Ar(93%)-CO2(7%) gas mixture at 3-bar pressure. The performance studies include the chamber calibration, the single-tube resolution, efficiency and electronic noise, and their behaviour as a function of the high-voltage setting and discriminator threshold. (C) 2003 Elsevier B.V. All rights reserved.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.