In this work we present, for the first time, a rapid, compact and innovative method for detection of Ochratoxin A ( OTA) based on hydrogenated amorphous silicon (a-Si: H) sensors. 2 mu l of acidified toluene containing OTA at different concentrations were spotted on the silica side of a High Performance Thin Layer Cromatography plate and aligned with a a-Si: H p- i- n photodiode deposited by Plasma Enhanced Chemical Vapor Deposition on a different glass substrate. As an UV radiation excites the mycotoxin, the re-emitted light is detected by the a- Si: H sensor. Results show a very good linearity between OTA concentration and the sensor photocurrent over almost three orders of magnitude. The minimum detected OTA concentration is equal to 0.1ng, showing that the presented system has the potential for a low cost system suitable for the early detection of toxins in foods.

Innovative detection system of ochratoxin a by thin film photodiodes / Caputo, Domenico; DE CESARE, Giampiero; Fanelli, Corrado; Nascetti, Augusto; Alessandra, Ricelli; Scipinotti, Riccardo. - In: SENSORS. - ISSN 1424-8220. - 7:7(2007), pp. 1317-1322. [10.3390/s7071317]

Innovative detection system of ochratoxin a by thin film photodiodes

CAPUTO, Domenico;DE CESARE, Giampiero;FANELLI, Corrado;NASCETTI, Augusto;SCIPINOTTI, RICCARDO
2007

Abstract

In this work we present, for the first time, a rapid, compact and innovative method for detection of Ochratoxin A ( OTA) based on hydrogenated amorphous silicon (a-Si: H) sensors. 2 mu l of acidified toluene containing OTA at different concentrations were spotted on the silica side of a High Performance Thin Layer Cromatography plate and aligned with a a-Si: H p- i- n photodiode deposited by Plasma Enhanced Chemical Vapor Deposition on a different glass substrate. As an UV radiation excites the mycotoxin, the re-emitted light is detected by the a- Si: H sensor. Results show a very good linearity between OTA concentration and the sensor photocurrent over almost three orders of magnitude. The minimum detected OTA concentration is equal to 0.1ng, showing that the presented system has the potential for a low cost system suitable for the early detection of toxins in foods.
2007
mycotoxin detection; photosensor; amorphous silicon; ochratoxin a
01 Pubblicazione su rivista::01a Articolo in rivista
Innovative detection system of ochratoxin a by thin film photodiodes / Caputo, Domenico; DE CESARE, Giampiero; Fanelli, Corrado; Nascetti, Augusto; Alessandra, Ricelli; Scipinotti, Riccardo. - In: SENSORS. - ISSN 1424-8220. - 7:7(2007), pp. 1317-1322. [10.3390/s7071317]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/231598
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 22
  • ???jsp.display-item.citation.isi??? 17
social impact