The contribution of explosive trace detection in samples from the hands of suspects has been fundamental in several forensic cases involving terrorists. This paper describes a method for the rapid extraction and unequivocal confirmation of some high potential explosives (trinitrotoluene, cyclotrimethylenetrinitramine, pentaerythritol tetranitrate, nitroglycerin) and two stabilizer (diphenylamine and ethylcentralite) residues in hand-swabs using liquid chromatography-tandem mass spectrometry. The extraction procedure of the analytes from the swabs is realized by solvent elution and the extracts are directly analyzed. Recoveries from spiked swabs range from 78 to 96%; the limits of quantification are between 0.04 and 1.8 ng injected and the inter-day method precision is less than 15%. The developed procedure was applied to the detection of explosives traces in samples after handling tests.

LC–MS–MS DETERMINATION OF STABILIZERS AND EXPLOSIVES RESIDUES IN HAND-SWABS / Perret, Daniela; Gentili, Alessandra; Marchese, Stefano; Curini, Roberta; Terracciano, Alessandro; Bafile, Eleonora; Romolo, Francesco Saverio. - In: CHROMATOGRAPHIA. - ISSN 0009-5893. - STAMPA. - 68:7-8(2008), pp. 517-524. [10.1365/s10337-008-0746-8]

LC–MS–MS DETERMINATION OF STABILIZERS AND EXPLOSIVES RESIDUES IN HAND-SWABS

PERRET, Daniela;GENTILI, Alessandra;MARCHESE, Stefano;CURINI, Roberta;TERRACCIANO, alessandro;BAFILE, Eleonora;ROMOLO, Francesco Saverio
2008

Abstract

The contribution of explosive trace detection in samples from the hands of suspects has been fundamental in several forensic cases involving terrorists. This paper describes a method for the rapid extraction and unequivocal confirmation of some high potential explosives (trinitrotoluene, cyclotrimethylenetrinitramine, pentaerythritol tetranitrate, nitroglycerin) and two stabilizer (diphenylamine and ethylcentralite) residues in hand-swabs using liquid chromatography-tandem mass spectrometry. The extraction procedure of the analytes from the swabs is realized by solvent elution and the extracts are directly analyzed. Recoveries from spiked swabs range from 78 to 96%; the limits of quantification are between 0.04 and 1.8 ng injected and the inter-day method precision is less than 15%. The developed procedure was applied to the detection of explosives traces in samples after handling tests.
2008
explosive residues; forensic science; HPLC-MS/MS
01 Pubblicazione su rivista::01a Articolo in rivista
LC–MS–MS DETERMINATION OF STABILIZERS AND EXPLOSIVES RESIDUES IN HAND-SWABS / Perret, Daniela; Gentili, Alessandra; Marchese, Stefano; Curini, Roberta; Terracciano, Alessandro; Bafile, Eleonora; Romolo, Francesco Saverio. - In: CHROMATOGRAPHIA. - ISSN 0009-5893. - STAMPA. - 68:7-8(2008), pp. 517-524. [10.1365/s10337-008-0746-8]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/230793
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 65
  • ???jsp.display-item.citation.isi??? 59
social impact