The last year we fabricated some new immunosensors for the analysis of lactoferrin protein. In the present research the immunological and analytical characteristics of the immunosensor method have been extensively investigated. The study was therefore extended to cover the ability of the analyte and the corresponding antibody to produce the immunocomplex. A rough estimation of the K(aff) value was obtained at the midpoint of the Langmuir curve, where K(aff) = 1/IC(50). The K(aff) value was found to be of the order of 10(6) M(-1). In addition we attempted in the present study to reduce the excessively long time required for each measurement, due to the fact that, in the previous researches the measurement procedure used was the classic "competition" ELISA type, employing an ad hoc enzymatic marker. One possible way of reducing measurement time was found to be to perform a kind of completely innovative "direct" measurement developed by us, which still uses an enzymatic marker and an amperometric transducer, as in the previous competition method. (C) 2010 Elsevier B.V. All rights reserved.

Further development of lactoferrin immunosensor (part III) / Campanella, Luigi; Martini, Elisabetta; Tomassetti, Mauro. - In: JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS. - ISSN 0731-7085. - STAMPA. - 53:2(2010), pp. 186-193. (Intervento presentato al convegno 13th International Meeting on Recent Development in Pharmaceutical Analysis tenutosi a Milan, ITALY nel SEP, 2009) [10.1016/j.jpba.2010.03.020].

Further development of lactoferrin immunosensor (part III)

CAMPANELLA, Luigi;MARTINI, ELISABETTA;TOMASSETTI, Mauro
2010

Abstract

The last year we fabricated some new immunosensors for the analysis of lactoferrin protein. In the present research the immunological and analytical characteristics of the immunosensor method have been extensively investigated. The study was therefore extended to cover the ability of the analyte and the corresponding antibody to produce the immunocomplex. A rough estimation of the K(aff) value was obtained at the midpoint of the Langmuir curve, where K(aff) = 1/IC(50). The K(aff) value was found to be of the order of 10(6) M(-1). In addition we attempted in the present study to reduce the excessively long time required for each measurement, due to the fact that, in the previous researches the measurement procedure used was the classic "competition" ELISA type, employing an ad hoc enzymatic marker. One possible way of reducing measurement time was found to be to perform a kind of completely innovative "direct" measurement developed by us, which still uses an enzymatic marker and an amperometric transducer, as in the previous competition method. (C) 2010 Elsevier B.V. All rights reserved.
2010
"direct" method; directandquot; human saliva; immunosensor; lactoferrin; method; pharmaceutical dairy products; quot
01 Pubblicazione su rivista::01a Articolo in rivista
Further development of lactoferrin immunosensor (part III) / Campanella, Luigi; Martini, Elisabetta; Tomassetti, Mauro. - In: JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS. - ISSN 0731-7085. - STAMPA. - 53:2(2010), pp. 186-193. (Intervento presentato al convegno 13th International Meeting on Recent Development in Pharmaceutical Analysis tenutosi a Milan, ITALY nel SEP, 2009) [10.1016/j.jpba.2010.03.020].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/230457
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 12
  • ???jsp.display-item.citation.isi??? 11
social impact