Tomographic images are obtained for few soft materials with multi-structure, cylinder with holes of different diameter and biological soft tissue. 2D images are obtained in the transmission mode. 3D images are reconstructed with the use of 2D slices for visualization of the internal structure. We obtained a series of images in the region 24-27 keV. 3D visualization of the materials is processed and analyzed the results. The present study is also focused on few geometrical considerations in order to design the collimators in front of the fluorescent source to improve the geometrical efficiency. (c) 2005 Elsevier Ltd. All rights reserved.

Tomographic images of few soft materials and embedded biological soft tissue using tube source of X-rays at optimum energy / D. V., Rao; T., Yuasa; T., Akatsuka; R., Cesareo; Gigante, Giovanni Ettore. - In: NDT & E INTERNATIONAL. - ISSN 0963-8695. - 39:1(2006), pp. 34-38. [10.1016/j.ndteint.2005.05.007]

Tomographic images of few soft materials and embedded biological soft tissue using tube source of X-rays at optimum energy

GIGANTE, Giovanni Ettore
2006

Abstract

Tomographic images are obtained for few soft materials with multi-structure, cylinder with holes of different diameter and biological soft tissue. 2D images are obtained in the transmission mode. 3D images are reconstructed with the use of 2D slices for visualization of the internal structure. We obtained a series of images in the region 24-27 keV. 3D visualization of the materials is processed and analyzed the results. The present study is also focused on few geometrical considerations in order to design the collimators in front of the fluorescent source to improve the geometrical efficiency. (c) 2005 Elsevier Ltd. All rights reserved.
2006
3d visualization; internal structure and geometrical approximations; soft materials; tomographic images
01 Pubblicazione su rivista::01a Articolo in rivista
Tomographic images of few soft materials and embedded biological soft tissue using tube source of X-rays at optimum energy / D. V., Rao; T., Yuasa; T., Akatsuka; R., Cesareo; Gigante, Giovanni Ettore. - In: NDT & E INTERNATIONAL. - ISSN 0963-8695. - 39:1(2006), pp. 34-38. [10.1016/j.ndteint.2005.05.007]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/22886
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact