To prospectively investigate the diagnostic accuracy of a 64-section multi-detector row computed tomography (CT) for the detection of peritoneal metastases, with the use of surgery and histopathological findings as the reference standard. The study cohort comprised 18 patients with peritoneal carcinomatosis who underwent multiphasic CT with a 64-section CT, 0-119 days before cytoreductive surgery. Transverse CT images along with isotropic reformatted coronal and sagittal images were prospectively and independently evaluated by one of the five staff radiologists in an unblinded fashion. The overall sensitivity, specificity, positive, and negative predictive values of CT for the detection of peritoneal metastases were, respectively, 75% (93 of 124 lesions; confidence interval [CI] 68-84), 92% (118 of 128; CI 85-96), 90% (93 of 103; CI 83-95), and 79% (118 of 149; CI 72-86). For lesions 0.5 cm in diameter or larger, CT yielded a mean sensitivity of 89% (77 of 87; CI 75-97), although sensitivity decreased to only 43% (16 of 37; CI 28-56) for lesions < 0.5 cm in diameter. 64-Section CT with the addition of isotropic reformatted coronal and sagittal images is a very effective technique in the detection of peritoneal metastases of 0.5 cm in diameter or larger, although sensitivity decreases remarkably for lesions < 0.5 cm in diameter.

64-Section multi-detector row CT in the preoperative diagnosis of peritoneal carcinomatosis: correlation with histopathological findings / Marin, Daniele; Catalano, Carlo; Mahbubeh, Baski; DI MARTINO, Michele; Geiger, Daniel; DI GIORGIO, Angelo; Sibio, Simone; Passariello, Roberto. - In: ABDOMINAL IMAGING. - ISSN 0942-8925. - STAMPA. - 35:6(2010), pp. 694-700. [10.1007/s00261-008-9464-9]

64-Section multi-detector row CT in the preoperative diagnosis of peritoneal carcinomatosis: correlation with histopathological findings

MARIN, DANIELE;CATALANO, Carlo;DI MARTINO, MICHELE;GEIGER, DANIEL;DI GIORGIO, Angelo;SIBIO, SIMONE;PASSARIELLO, Roberto
2010

Abstract

To prospectively investigate the diagnostic accuracy of a 64-section multi-detector row computed tomography (CT) for the detection of peritoneal metastases, with the use of surgery and histopathological findings as the reference standard. The study cohort comprised 18 patients with peritoneal carcinomatosis who underwent multiphasic CT with a 64-section CT, 0-119 days before cytoreductive surgery. Transverse CT images along with isotropic reformatted coronal and sagittal images were prospectively and independently evaluated by one of the five staff radiologists in an unblinded fashion. The overall sensitivity, specificity, positive, and negative predictive values of CT for the detection of peritoneal metastases were, respectively, 75% (93 of 124 lesions; confidence interval [CI] 68-84), 92% (118 of 128; CI 85-96), 90% (93 of 103; CI 83-95), and 79% (118 of 149; CI 72-86). For lesions 0.5 cm in diameter or larger, CT yielded a mean sensitivity of 89% (77 of 87; CI 75-97), although sensitivity decreased to only 43% (16 of 37; CI 28-56) for lesions < 0.5 cm in diameter. 64-Section CT with the addition of isotropic reformatted coronal and sagittal images is a very effective technique in the detection of peritoneal metastases of 0.5 cm in diameter or larger, although sensitivity decreases remarkably for lesions < 0.5 cm in diameter.
2010
peritoneal neoplasms; diagnostic accuracy; computed tomography; multiplanar reformations (mpr); peritoneal carcinomatosis
01 Pubblicazione su rivista::01a Articolo in rivista
64-Section multi-detector row CT in the preoperative diagnosis of peritoneal carcinomatosis: correlation with histopathological findings / Marin, Daniele; Catalano, Carlo; Mahbubeh, Baski; DI MARTINO, Michele; Geiger, Daniel; DI GIORGIO, Angelo; Sibio, Simone; Passariello, Roberto. - In: ABDOMINAL IMAGING. - ISSN 0942-8925. - STAMPA. - 35:6(2010), pp. 694-700. [10.1007/s00261-008-9464-9]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/227498
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 22
  • Scopus 80
  • ???jsp.display-item.citation.isi??? 66
social impact