In this paper, power absorption and temperature elevation in the thorax of a pacemaker (PM) holder exposed to the field generated by a 1.5-T (64 MHz) magnetic resonance imaging (MRI) apparatus have been studied. An anatomical body model has been placed in two different positions inside the birdcage MRI antenna. Various PM models, constituted by a metallic box equipped with different kinds of catheters, have been placed in some typical positions inside the human thorax. The obtained results showthat in the absence of the PM, both specific absorption rate (SAR) levels and temperature increments are compliant with the recommendations contained in international guidelines. When a realistic model of the PM is inserted inside the body, the limits on the whole body SAR are still met, the limits on SAR averaged over 10 g are exceeded for some catheter geometries, while temperature increments at the catheter tip are above the prescribed recommendations.

Power Absorption and Temperature Elevation Produced by Magnetic Resonance Apparatus in the Thorax of Patients With Implanted Pacemakers / Pisa, Stefano; Bernardi, Paolo Italo; Cavagnaro, Marta; Piuzzi, Emanuele. - In: IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY. - ISSN 0018-9375. - 52:1(2010), pp. 32-40. [10.1109/temc.2009.2034643]

Power Absorption and Temperature Elevation Produced by Magnetic Resonance Apparatus in the Thorax of Patients With Implanted Pacemakers

PISA, Stefano;BERNARDI, Paolo Italo;CAVAGNARO, Marta;PIUZZI, Emanuele
2010

Abstract

In this paper, power absorption and temperature elevation in the thorax of a pacemaker (PM) holder exposed to the field generated by a 1.5-T (64 MHz) magnetic resonance imaging (MRI) apparatus have been studied. An anatomical body model has been placed in two different positions inside the birdcage MRI antenna. Various PM models, constituted by a metallic box equipped with different kinds of catheters, have been placed in some typical positions inside the human thorax. The obtained results showthat in the absence of the PM, both specific absorption rate (SAR) levels and temperature increments are compliant with the recommendations contained in international guidelines. When a realistic model of the PM is inserted inside the body, the limits on the whole body SAR are still met, the limits on SAR averaged over 10 g are exceeded for some catheter geometries, while temperature increments at the catheter tip are above the prescribed recommendations.
2010
dosimetry; cardiac pacemakers; magnetic resonance imaging (mri); temperature
01 Pubblicazione su rivista::01a Articolo in rivista
Power Absorption and Temperature Elevation Produced by Magnetic Resonance Apparatus in the Thorax of Patients With Implanted Pacemakers / Pisa, Stefano; Bernardi, Paolo Italo; Cavagnaro, Marta; Piuzzi, Emanuele. - In: IEEE TRANSACTIONS ON ELECTROMAGNETIC COMPATIBILITY. - ISSN 0018-9375. - 52:1(2010), pp. 32-40. [10.1109/temc.2009.2034643]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/226853
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 15
  • ???jsp.display-item.citation.isi??? 13
social impact