The earthquake causes serious problems to the functional reliability and continuity of supply of electrical power systems particularly in exposed and sensitive structures as hospitals and strategic buildings. The paper discusses the need to study the requirements for the design and installation of electrical power systems in buildings subject to seismic hazard. Mechanical and electrical criteria for the design and the installation are recommended to be graduated according to building occupancy categories (as hospitals, strategic buildings). At least three levels of performance are identified for equipment. An important goal is to coordinate the non structural designing criteria with a layout of the system architecture that avoids or confines as possible intrinsically in a "duty-free" zone the seismic exposition and limits the same installation problems. A special power distribution, "brush- distribution", has a laid structure suitably for the strategic buildings that are at risk for seismic event. Other general design criteria, such as a guarantee for the supply continuity, the system reliability and the system protection, have a special use in these appliances. The paper compares the brush distribution against the recommendations for the non structural components issued by the National Earthquake Hazard Reduction Program (NEHRP) (edition 2009). © IEEE 2010.

Electrical power systems availability in buildings exposed to seismic hazard / Parise, Giuseppe; Martirano, Luigi; Gary, Fox. - STAMPA. - (2010), pp. 1-8. (Intervento presentato al convegno 2010 IEEE Industrial and Commercial Power Systems Technical Conference, I and CPS 2010 tenutosi a Tallahassee, FL nel 9 May 2010 through 13 May 2010) [10.1109/icps.2010.5489896].

Electrical power systems availability in buildings exposed to seismic hazard

PARISE, Giuseppe;MARTIRANO, Luigi;
2010

Abstract

The earthquake causes serious problems to the functional reliability and continuity of supply of electrical power systems particularly in exposed and sensitive structures as hospitals and strategic buildings. The paper discusses the need to study the requirements for the design and installation of electrical power systems in buildings subject to seismic hazard. Mechanical and electrical criteria for the design and the installation are recommended to be graduated according to building occupancy categories (as hospitals, strategic buildings). At least three levels of performance are identified for equipment. An important goal is to coordinate the non structural designing criteria with a layout of the system architecture that avoids or confines as possible intrinsically in a "duty-free" zone the seismic exposition and limits the same installation problems. A special power distribution, "brush- distribution", has a laid structure suitably for the strategic buildings that are at risk for seismic event. Other general design criteria, such as a guarantee for the supply continuity, the system reliability and the system protection, have a special use in these appliances. The paper compares the brush distribution against the recommendations for the non structural components issued by the National Earthquake Hazard Reduction Program (NEHRP) (edition 2009). © IEEE 2010.
2010
2010 IEEE Industrial and Commercial Power Systems Technical Conference, I and CPS 2010
availability; electrical distribution; seismic risk
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Electrical power systems availability in buildings exposed to seismic hazard / Parise, Giuseppe; Martirano, Luigi; Gary, Fox. - STAMPA. - (2010), pp. 1-8. (Intervento presentato al convegno 2010 IEEE Industrial and Commercial Power Systems Technical Conference, I and CPS 2010 tenutosi a Tallahassee, FL nel 9 May 2010 through 13 May 2010) [10.1109/icps.2010.5489896].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/225802
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact