Images of small plastic and food materials are obtained using a tomographic device based on image intensifier at optimum energy. The nux emitted by the X-ray tube is filtered using appropriate filters at the chosen optimum energy and reasonable monochromacy is achieved and the images are acceptably distinct. X-ray imaging is an established technique of detecting strongly attenuating materials as distinguished from weakly attenuating materials. The image contrast between the weakly attenuating materials can be enhanced by optimum selection of the energy and improving the spatial resolution. The image contrast between soft materials could be significantly enhanced by optimal selection of the energy of the X-rays using Monte Carlo methods. The images are analyzed using the profile data showing the internal defect of the object. It offers a new nondestructive method using the ionizing radiation techniques. With optimum value of energy and improving the spatial resolution the image contrast of the weakly attenuating materials can be improved considerably.

Imaging of small objects and soft materials at optimum energy using tomographic device based on image intensifier / Rao, D. V.; S. M., Seltzer; J. H., Hubbell; Gigante, Giovanni Ettore. - STAMPA. - 4142:(2000), pp. 297-307. (Intervento presentato al convegno Conference on Penetrating Radiation Systems and Applications II tenutosi a SAN DIEGO, CA nel 2-3 Agosto 2000) [10.1117/12.410578].

Imaging of small objects and soft materials at optimum energy using tomographic device based on image intensifier

GIGANTE, Giovanni Ettore
2000

Abstract

Images of small plastic and food materials are obtained using a tomographic device based on image intensifier at optimum energy. The nux emitted by the X-ray tube is filtered using appropriate filters at the chosen optimum energy and reasonable monochromacy is achieved and the images are acceptably distinct. X-ray imaging is an established technique of detecting strongly attenuating materials as distinguished from weakly attenuating materials. The image contrast between the weakly attenuating materials can be enhanced by optimum selection of the energy and improving the spatial resolution. The image contrast between soft materials could be significantly enhanced by optimal selection of the energy of the X-rays using Monte Carlo methods. The images are analyzed using the profile data showing the internal defect of the object. It offers a new nondestructive method using the ionizing radiation techniques. With optimum value of energy and improving the spatial resolution the image contrast of the weakly attenuating materials can be improved considerably.
2000
PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS (SPIE)
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/188567
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 3
  • ???jsp.display-item.citation.isi??? 3
social impact