Fixation disparity, that is, misalignment of the gaze direction of both eyes, may be observed in static conditions (through standard optometric evaluation) and dynamic conditions (through eye movement recording). A computation method is presented to determine vergence angles and fixation disparity from gaze positions as commonly recorded by infrared eye-trackers when a participant looks at a personal computer (PC) screen. Eye-tracking devices provide gaze position in coordinates relative to the bidimensional screen surface. From these data, vergence angles can be calculated by trigonometric triangulations; fixation disparity is then calculated from the vergence angles. The application of the procedure to the recordings of one participant is described. To control for the effective alignment of the two eyes on the target during binocular calibration, a procedure based on the dichoptic presentation of nonius lines was used. The recordings confirm that computation and the dichoptic calibration procedures ensure reliable measures of vergence and fixation disparity. The usefulness of this approach with infrared recording of eye position is discussed.

Measuring fixation disparity with infrared eye trackers / DE LUCA, M; Spinelli, D; Zeri, F; Zoccolotti, Pierluigi. - In: JOURNAL OF BIOMEDICAL OPTICS. - ISSN 1083-3668. - STAMPA. - 14:1(2009), pp. 1-8. [10.1117/1.3077198]

Measuring fixation disparity with infrared eye trackers.

ZOCCOLOTTI, Pierluigi
2009

Abstract

Fixation disparity, that is, misalignment of the gaze direction of both eyes, may be observed in static conditions (through standard optometric evaluation) and dynamic conditions (through eye movement recording). A computation method is presented to determine vergence angles and fixation disparity from gaze positions as commonly recorded by infrared eye-trackers when a participant looks at a personal computer (PC) screen. Eye-tracking devices provide gaze position in coordinates relative to the bidimensional screen surface. From these data, vergence angles can be calculated by trigonometric triangulations; fixation disparity is then calculated from the vergence angles. The application of the procedure to the recordings of one participant is described. To control for the effective alignment of the two eyes on the target during binocular calibration, a procedure based on the dichoptic presentation of nonius lines was used. The recordings confirm that computation and the dichoptic calibration procedures ensure reliable measures of vergence and fixation disparity. The usefulness of this approach with infrared recording of eye position is discussed.
2009
01 Pubblicazione su rivista::01a Articolo in rivista
Measuring fixation disparity with infrared eye trackers / DE LUCA, M; Spinelli, D; Zeri, F; Zoccolotti, Pierluigi. - In: JOURNAL OF BIOMEDICAL OPTICS. - ISSN 1083-3668. - STAMPA. - 14:1(2009), pp. 1-8. [10.1117/1.3077198]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/18283
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? 2
  • Scopus 7
  • ???jsp.display-item.citation.isi??? 7
social impact