This work presents a physics-informed normal behaviour modelling approach for wind turbine gearbox condition monitoring based on SCADA data. The methodology relies on a Physics-Informed Autoencoder, in which a thermo-dynamic model of the gearbox is embedded into the training loss to incorporate domain knowledge into the learning process. SCADA signals related to gearbox operation are used to train the model under healthy conditions, allowing the characterisation of normal gearbox behaviour. Anomaly detection is performed by monitoring the reconstruction error and applying a CUSUM-based detection scheme to assess the persistence of deviations. The approach is validated using a public dataset provided by EDP Renewables, comprising SCADA data from four wind turbines. Results show that the proposed framework is capable of detecting a documented “Gearbox pump damaged” fault event five days in advance, without generating false alarms during normal operation.
Towards Physics-Informed Multi-Component Normal Behaviour Modelling for Wind Turbines: A Gearbox Case Study / Ancora, T.C.M., Barnabei, V.F., Corsini, A., Gambadori, L., Milani, A.E., Zappalà, D., Watson, S.. - In: JOURNAL OF PHYSICS. CONFERENCE SERIES. - ISSN 1742-6588. - 3224:6(2026). (Science of Making Torque from Wind 2026 TORQUE 2026 Bruges ) [10.1088/1742-6596/3224/6/062051].
Towards Physics-Informed Multi-Component Normal Behaviour Modelling for Wind Turbines: A Gearbox Case Study
Ancora, T C M;Barnabei, V F;Corsini, A;Gambadori, L;
2026
Abstract
This work presents a physics-informed normal behaviour modelling approach for wind turbine gearbox condition monitoring based on SCADA data. The methodology relies on a Physics-Informed Autoencoder, in which a thermo-dynamic model of the gearbox is embedded into the training loss to incorporate domain knowledge into the learning process. SCADA signals related to gearbox operation are used to train the model under healthy conditions, allowing the characterisation of normal gearbox behaviour. Anomaly detection is performed by monitoring the reconstruction error and applying a CUSUM-based detection scheme to assess the persistence of deviations. The approach is validated using a public dataset provided by EDP Renewables, comprising SCADA data from four wind turbines. Results show that the proposed framework is capable of detecting a documented “Gearbox pump damaged” fault event five days in advance, without generating false alarms during normal operation.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.


