The Cryogenic Underground Observatory for Rare Events (CUORE) experiment set the most stringent limit on the neutrinoless double-beta (0νββ) decay half-life of 130Te with 2 t·yr TeO2 analyzed exposure. In addition to 0νββ decay, the CUORE detector—a ton-scale array of nearly 1000 cryogenic calorimeters operating at ∼10 mK—is capable of searching for other rare decays and interactions over a broad energy range. For our searches, we leverage the available information of each calorimeter by performing its optimization, data acquisition, and analysis independently. We describe the analysis tools and methods developed for CUORE and their application to build high-quality datasets for numerous physics searches. In particular, we describe in detail our evaluation of the energy-dependent detector response and signal efficiency used in the most recent search for 0νββ decay.

End-to-end data analysis methods for the CUORE experiment / Adams, D.Q., Alduino, C., Alfonso, K., Armatol, A., Avignone, F.T., Azzolini, O., Bari, G., Bellini, F., Benato, G., Beretta, M., Biassoni, M., Branca, A., Brofferio, C., Bucci, C., Camilleri, J., Caminata, A., Campani, A., Cao, J., Capelli, C., Capelli, S., et al.. - In: THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS. - ISSN 1434-6044. - 86:10(2026). [10.1140/epjc/s10052-026-16350-3]

End-to-end data analysis methods for the CUORE experiment

Bellini, F.;Ressa, A.;
2026

Abstract

The Cryogenic Underground Observatory for Rare Events (CUORE) experiment set the most stringent limit on the neutrinoless double-beta (0νββ) decay half-life of 130Te with 2 t·yr TeO2 analyzed exposure. In addition to 0νββ decay, the CUORE detector—a ton-scale array of nearly 1000 cryogenic calorimeters operating at ∼10 mK—is capable of searching for other rare decays and interactions over a broad energy range. For our searches, we leverage the available information of each calorimeter by performing its optimization, data acquisition, and analysis independently. We describe the analysis tools and methods developed for CUORE and their application to build high-quality datasets for numerous physics searches. In particular, we describe in detail our evaluation of the energy-dependent detector response and signal efficiency used in the most recent search for 0νββ decay.
2026
cryogenic calorimeter; neutrinoless double beta decay; Majorana neutrino
01 Pubblicazione su rivista::01a Articolo in rivista
End-to-end data analysis methods for the CUORE experiment / Adams, D.Q., Alduino, C., Alfonso, K., Armatol, A., Avignone, F.T., Azzolini, O., Bari, G., Bellini, F., Benato, G., Beretta, M., Biassoni, M., Branca, A., Brofferio, C., Bucci, C., Camilleri, J., Caminata, A., Campani, A., Cao, J., Capelli, C., Capelli, S., et al.. - In: THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS. - ISSN 1434-6044. - 86:10(2026). [10.1140/epjc/s10052-026-16350-3]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1781976
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact