Ultra-wideband (UWB) positioning systems are strongly affected by non-line-of-sight (NLOS) propagation, since obstructed ranges can introduce systematic positioning errors. Channel impulse response (CIR) measurements enable supervised LOS/NLOS classification, but verified labels are expensive to obtain for every new physical environment, whereas unlabeled CIR samples are naturally collected during deployment. This paper studies whether self-training can exploit such unlabeled UWB data without overstating generalization. We use a compact one-dimensional CNN and compare three protocols on an industrial UWB dataset collected at 18 locations, of which seven are labeled and eleven are unlabeled: a supervised seven-location baseline (SL-7), strict seven-location self-training (ST-7), and extended eighteen-location self-training (ST-18). SL-7 reaches 95.51% mean macro-F1 with 99.68% NLOS recall. ST-7 reaches the same mean macro-F1 at a confidence threshold of τ =0.90 and is therefore indistinguishable from SL-7, but changes the error balance by improving LOS recall while reducing NLOS recall. ST-18 does not improve over SL-7. These results show that standard high-confidence self-training is not reliably beneficial under physical location shift.

Supervised and Semi-Supervised UWB LOS/NLOS Classification in Industrial Environments / Bouzar, N., De Nardis, L., Elbahhar, F., Di Benedetto, M.. - (2026), pp. 1-6. (2026 International Conference on Indoor Positioning and Indoor Navigation (IPIN) Roma; Italia ) [10.1109/ipin72673.2026.11772541].

Supervised and Semi-Supervised UWB LOS/NLOS Classification in Industrial Environments

Bouzar, Nadir
;
De Nardis, Luca;Di Benedetto, Maria-Gabriella
2026

Abstract

Ultra-wideband (UWB) positioning systems are strongly affected by non-line-of-sight (NLOS) propagation, since obstructed ranges can introduce systematic positioning errors. Channel impulse response (CIR) measurements enable supervised LOS/NLOS classification, but verified labels are expensive to obtain for every new physical environment, whereas unlabeled CIR samples are naturally collected during deployment. This paper studies whether self-training can exploit such unlabeled UWB data without overstating generalization. We use a compact one-dimensional CNN and compare three protocols on an industrial UWB dataset collected at 18 locations, of which seven are labeled and eleven are unlabeled: a supervised seven-location baseline (SL-7), strict seven-location self-training (ST-7), and extended eighteen-location self-training (ST-18). SL-7 reaches 95.51% mean macro-F1 with 99.68% NLOS recall. ST-7 reaches the same mean macro-F1 at a confidence threshold of τ =0.90 and is therefore indistinguishable from SL-7, but changes the error balance by improving LOS recall while reducing NLOS recall. ST-18 does not improve over SL-7. These results show that standard high-confidence self-training is not reliably beneficial under physical location shift.
2026
2026 International Conference on Indoor Positioning and Indoor Navigation (IPIN)
Ultra-wideband; LOS/NLOS Classification; Channel Impulse Response
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Supervised and Semi-Supervised UWB LOS/NLOS Classification in Industrial Environments / Bouzar, N., De Nardis, L., Elbahhar, F., Di Benedetto, M.. - (2026), pp. 1-6. (2026 International Conference on Indoor Positioning and Indoor Navigation (IPIN) Roma; Italia ) [10.1109/ipin72673.2026.11772541].
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1781709
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact