We report on the Geant4 Monte Carlo simulation work for the non–X-ray background (NXB) of the NewAthena X-ray Integral Field Unit (X-IFU), focusing on mass model updates, advanced veto strategies, and validation against laboratory data. The simulations’ mass model evolved in parallel with the mission redefinition work, incorporating new and updated geometries of the cryostat and Focal Plane Assembly (FPA), L-grooves, and updated absorber layouts. High-statistics simulations revealed modest changes in background levels relative to the 2017 mass model and confirmed spatial homogeneity of the background across the TES array. Although the design is not yet finalized in all its elements, the representativeness of the results increased with respect to previous results. We also tested a partial veto strategy exploiting the segmented nature of the Cryogenic AntiCoincidence detector (CryoAC). By restricting vetoes to the sector of the TES array directly above the triggered CryoAC pixel, we maintain 75% of the main array active at the cost of a 50% NXB increase. Extending the veto region by ∆ pixels rapidly mitigates this effect, lowering the background increment to 6% already for ∆ = 5. A preliminary simulation of solar energetic particle event confirmed the expected background levels exceeding mission requirements by three orders of magnitude for scientific observations during such an event. Finally, validation against laboratory measurements with CryoAC detector prototypes demonstrated strong agreement between simulated and observed data, highlighting the importance of accurate mass model and radiative environment representation for simulation reliability.
NewAthena X-IFU non-x-ray background: veto optimization and laboratory validation / Lotti, S., Monastra, F., Gorla, G., D'Andrea, M., Chrysaphi, N., Laurenza, M., Macculi, C., Piro, L.. - (2026). (SPIE Astronomical Telescopes + Instrumentation Copenaghen ) [10.1117/12.3104565].
NewAthena X-IFU non-x-ray background: veto optimization and laboratory validation
Monastra, Francesco;Gorla, Giacomo;D'Andrea, Matteo;Laurenza, Monica;Piro, Luigi
2026
Abstract
We report on the Geant4 Monte Carlo simulation work for the non–X-ray background (NXB) of the NewAthena X-ray Integral Field Unit (X-IFU), focusing on mass model updates, advanced veto strategies, and validation against laboratory data. The simulations’ mass model evolved in parallel with the mission redefinition work, incorporating new and updated geometries of the cryostat and Focal Plane Assembly (FPA), L-grooves, and updated absorber layouts. High-statistics simulations revealed modest changes in background levels relative to the 2017 mass model and confirmed spatial homogeneity of the background across the TES array. Although the design is not yet finalized in all its elements, the representativeness of the results increased with respect to previous results. We also tested a partial veto strategy exploiting the segmented nature of the Cryogenic AntiCoincidence detector (CryoAC). By restricting vetoes to the sector of the TES array directly above the triggered CryoAC pixel, we maintain 75% of the main array active at the cost of a 50% NXB increase. Extending the veto region by ∆ pixels rapidly mitigates this effect, lowering the background increment to 6% already for ∆ = 5. A preliminary simulation of solar energetic particle event confirmed the expected background levels exceeding mission requirements by three orders of magnitude for scientific observations during such an event. Finally, validation against laboratory measurements with CryoAC detector prototypes demonstrated strong agreement between simulated and observed data, highlighting the importance of accurate mass model and radiative environment representation for simulation reliability.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.