The Cryogenic Anticoincidence (CryoAC) detector is a critical subsystem designed to reduce the particle background for the X-ray Integral Field Unit (X-IFU) instrument onboard the NewAthena space observatory, the next ESA X-ray Large mission. Advancing this technology to Technology Readiness Level 5 (TRL5) requires a unified validation spanning both cleanroom microfabrication repeatability and mK low temperature operational performance. This work presents the complete development cycle of the Demonstration Model 1.2 (DM 1.2), which is aimed at completing the TRL5 demonstration path featured by all the critical technologies operating simultaneously. First, single-process verification protocols were established for Iridium pulsed laser deposition, Reactive Ion Etching (RIE), and deep silicon trenching via the Bosch process. Second, three identical single-pixel prototypes were fabricated and subjected to mK characterization. Four-wire resistance measurement results confirmed a 2/3 production yield against strict design targets (TC ~100 mK). Finally, functional testing at a bath temperature of 50 mK using a VTT FAB4 SQUID readout demonstrated excellent performance, including a low-energy threshold of ~0.6 keV, a pixel power dissipation of 5.15 nW, and an energy resolution ΔEFWHM = 735 eV at 6 keV. These combined achievements successfully validate the entire manufacturing and operational baseline against all primary space mission requirements. This paper has to be considered as a review of the CryoAC technology path toward the TRL5 achievement; main findings will be reported and discussed. Details are relegated to other papers.

Developing the NewAthena X-IFU Cryogenic AntiCoincidence Detector (CryoAC): From Microfabrication Process Standardization to Cryogenic Functional Verification Toward TRL5 / Macculi, C., D'Andrea, M., Gorla, G., Lotti, S., Minervini, G., Monastra, F., Piro, L., Ferrari Barusso, L., Celasco, E., Gatti, F., Grosso, D., Rigano, M., Chiarello, F., Torrioli, G., Fiorini, M., Uslenghi, M., Brienza, D., Cavazzuti, E., Grappasonni, C., Puccetti, S., et al.. - In: SENSORS. - ISSN 1424-8220. - 26:15(2026). [10.3390/s26154985]

Developing the NewAthena X-IFU Cryogenic AntiCoincidence Detector (CryoAC): From Microfabrication Process Standardization to Cryogenic Functional Verification Toward TRL5

Gorla, Giacomo;Chiarello, Fabio;Torrioli, Guido;Brienza, Daniele;Grappasonni, Chiara;Bastia, Paolo;
2026

Abstract

The Cryogenic Anticoincidence (CryoAC) detector is a critical subsystem designed to reduce the particle background for the X-ray Integral Field Unit (X-IFU) instrument onboard the NewAthena space observatory, the next ESA X-ray Large mission. Advancing this technology to Technology Readiness Level 5 (TRL5) requires a unified validation spanning both cleanroom microfabrication repeatability and mK low temperature operational performance. This work presents the complete development cycle of the Demonstration Model 1.2 (DM 1.2), which is aimed at completing the TRL5 demonstration path featured by all the critical technologies operating simultaneously. First, single-process verification protocols were established for Iridium pulsed laser deposition, Reactive Ion Etching (RIE), and deep silicon trenching via the Bosch process. Second, three identical single-pixel prototypes were fabricated and subjected to mK characterization. Four-wire resistance measurement results confirmed a 2/3 production yield against strict design targets (TC ~100 mK). Finally, functional testing at a bath temperature of 50 mK using a VTT FAB4 SQUID readout demonstrated excellent performance, including a low-energy threshold of ~0.6 keV, a pixel power dissipation of 5.15 nW, and an energy resolution ΔEFWHM = 735 eV at 6 keV. These combined achievements successfully validate the entire manufacturing and operational baseline against all primary space mission requirements. This paper has to be considered as a review of the CryoAC technology path toward the TRL5 achievement; main findings will be reported and discussed. Details are relegated to other papers.
2026
Athena mission; CryoAC; cryogenic testing; microfabrication; pulsed laser deposition; SQUID; Transition Edge Sensors; X-IFU
01 Pubblicazione su rivista::01a Articolo in rivista
Developing the NewAthena X-IFU Cryogenic AntiCoincidence Detector (CryoAC): From Microfabrication Process Standardization to Cryogenic Functional Verification Toward TRL5 / Macculi, C., D'Andrea, M., Gorla, G., Lotti, S., Minervini, G., Monastra, F., Piro, L., Ferrari Barusso, L., Celasco, E., Gatti, F., Grosso, D., Rigano, M., Chiarello, F., Torrioli, G., Fiorini, M., Uslenghi, M., Brienza, D., Cavazzuti, E., Grappasonni, C., Puccetti, S., et al.. - In: SENSORS. - ISSN 1424-8220. - 26:15(2026). [10.3390/s26154985]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1781328
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact