Modern power systems are increasingly characterized by the integration of distributed energy resources, hybrid AC/DC architectures, and unbalanced operating conditions. These developments introduce significant challenges in accurately analyzing system behavior, particularly under short-circuit conditions where power electronic converters are subject to current limitations and control constraints. This paper presents a three-phase analysis framework for unbalanced short-circuit conditions in hybrid AC/DC power systems, incorporating detailed converter models with current limitation effects. The proposed approach employs an iterative phasor-domain solution in which network equations remain constant while converter current injections are updated based on voltage conditions and control strategies. Both coupled sequence control (CSC) and decoupled sequence control (DSC) schemes are considered to evaluate their impact on system performance. Simulation results demonstrate that converter behavior during fault conditions is strongly dependent on control strategy and operating limits. In particular, the DSC approach shows improved capability in mitigating voltage unbalance compared to CSC, although complete elimination of negative sequence components is not achieved. These findings highlight the importance of accurate converter modeling for reliable short-circuit analysis in modern hybrid power systems.
Three-Phase Analysis of Unbalanced Short-Circuit Conditions in Hybrid AC/DC Power Systems with Converter Current Limitations / Almughary, H., Bragatto, T., Geri, A., Khalid, H., Maccioni, M., Santori, F.. - (2026). (26th International Conference on Environment and Electrical Engineering and 10th Industrial and Commercial Power Systems Europe (EEEIC / I&CPS Europe) Lisbon; Portugal ).
Three-Phase Analysis of Unbalanced Short-Circuit Conditions in Hybrid AC/DC Power Systems with Converter Current Limitations
Almughary, Huda
Primo
Membro del Collaboration Group
;Bragatto, Tommaso;Geri, Alberto;Khalid, Hadid;Maccioni, Marco;Santori, Francesca
Membro del Collaboration Group
2026
Abstract
Modern power systems are increasingly characterized by the integration of distributed energy resources, hybrid AC/DC architectures, and unbalanced operating conditions. These developments introduce significant challenges in accurately analyzing system behavior, particularly under short-circuit conditions where power electronic converters are subject to current limitations and control constraints. This paper presents a three-phase analysis framework for unbalanced short-circuit conditions in hybrid AC/DC power systems, incorporating detailed converter models with current limitation effects. The proposed approach employs an iterative phasor-domain solution in which network equations remain constant while converter current injections are updated based on voltage conditions and control strategies. Both coupled sequence control (CSC) and decoupled sequence control (DSC) schemes are considered to evaluate their impact on system performance. Simulation results demonstrate that converter behavior during fault conditions is strongly dependent on control strategy and operating limits. In particular, the DSC approach shows improved capability in mitigating voltage unbalance compared to CSC, although complete elimination of negative sequence components is not achieved. These findings highlight the importance of accurate converter modeling for reliable short-circuit analysis in modern hybrid power systems.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.