Characterization of complex electromagnetic (EM) exposure scenarios is a challenging task, particularly when in presence of the human body. Standard dosimetric approaches estimate EM induced quantities through full-wave simulations that require a detailed model of both the source and the body [1]. As a consequence, even minor changes, such as a relative shift between the two, necessitate repeati ng the entire simulation process. This makes the development of fast computational methods of paramount importance, particularly whenever it is necessary to establish a clear correlation between adherence to Reference Levels (Fields) and compliance with Basic Restrictions (SAR), under multiple exposure conditions, such as those encountered in military applications. In this work we present a fast algorithm to calculate the electric (E-)field, and consequently evaluate the SAR, that an arbitrary source can induce inside a homogeneous virtual anthropomorphic model, by exploiting the source’s propagating Plane Wave Expansion (PWE) and by characterizing the intrinsic scattering properties of the dielectric volume independently of the source. For the latter, it is necessary to obtain the so called Exposure Matrix, a representative discrete linear mapping of each PW spectrum component onto the E-fields induced within the body. Hence, the homogeneous, anthropomorphic virtual phantom, possessing dielectric properties equivalent to 2/3 of human muscle’s [2], is placed over an infinite ground plane and exposed to a sequence of plane waves (PWs) with both transverse-electric (TE) and transverse-magnetic (TM) polarizations with respect to the z-axis (Fig. 1). A total of 828 simulations (648 in the UHF with ∆θ = ∆φ = 10◦ and 180 with ∆θ = ∆φ = 20◦ in the VHF bands), were performed using CST Microwave Studio (v. 2024) Time Domain Solver. Truncated Single Value Decomposition (TSVD) can be then applied, resulting in a minimum rank matrix, reducing the computation of fields within the given dielectric volume exposed to the arbitrary source to a matrix-vector multiplication, speeding-up the computation times. The reconstruction capability of the method has been tested for an arbitrary field configuration, randomly selected among the available exposure matrices (i.e., 250 MHz, |E| = 61 V/m, θ = 20°, ϕ = 220°). Results using the first 20 SVs showed that the reference configuration can be reconstructed with a median error (i.e., Symmetric Mean Percentage Error-SMAPE) of 4%, and the peak values can be obtained with a SMAPE within 1%.
Real-time dosimetric computation in homogeneous virtual models: a fast method in the HF to the low-UHF bands / Ferrante, D., Colella, M., Vecchi, G., Apollonio, F., Micaela Liberti, A.. - (2026). (URSI GASS 2026 Cracovia ).
Real-time dosimetric computation in homogeneous virtual models: a fast method in the HF to the low-UHF bands
Daniele Ferrante;Micol Colella;Giuseppe Vecchi;Francesca Apollonio;
2026
Abstract
Characterization of complex electromagnetic (EM) exposure scenarios is a challenging task, particularly when in presence of the human body. Standard dosimetric approaches estimate EM induced quantities through full-wave simulations that require a detailed model of both the source and the body [1]. As a consequence, even minor changes, such as a relative shift between the two, necessitate repeati ng the entire simulation process. This makes the development of fast computational methods of paramount importance, particularly whenever it is necessary to establish a clear correlation between adherence to Reference Levels (Fields) and compliance with Basic Restrictions (SAR), under multiple exposure conditions, such as those encountered in military applications. In this work we present a fast algorithm to calculate the electric (E-)field, and consequently evaluate the SAR, that an arbitrary source can induce inside a homogeneous virtual anthropomorphic model, by exploiting the source’s propagating Plane Wave Expansion (PWE) and by characterizing the intrinsic scattering properties of the dielectric volume independently of the source. For the latter, it is necessary to obtain the so called Exposure Matrix, a representative discrete linear mapping of each PW spectrum component onto the E-fields induced within the body. Hence, the homogeneous, anthropomorphic virtual phantom, possessing dielectric properties equivalent to 2/3 of human muscle’s [2], is placed over an infinite ground plane and exposed to a sequence of plane waves (PWs) with both transverse-electric (TE) and transverse-magnetic (TM) polarizations with respect to the z-axis (Fig. 1). A total of 828 simulations (648 in the UHF with ∆θ = ∆φ = 10◦ and 180 with ∆θ = ∆φ = 20◦ in the VHF bands), were performed using CST Microwave Studio (v. 2024) Time Domain Solver. Truncated Single Value Decomposition (TSVD) can be then applied, resulting in a minimum rank matrix, reducing the computation of fields within the given dielectric volume exposed to the arbitrary source to a matrix-vector multiplication, speeding-up the computation times. The reconstruction capability of the method has been tested for an arbitrary field configuration, randomly selected among the available exposure matrices (i.e., 250 MHz, |E| = 61 V/m, θ = 20°, ϕ = 220°). Results using the first 20 SVs showed that the reference configuration can be reconstructed with a median error (i.e., Symmetric Mean Percentage Error-SMAPE) of 4%, and the peak values can be obtained with a SMAPE within 1%.I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.