At millimeter-wave frequencies, electromagnetic energy deposition in the human body is confined to superficial tissues, making skin modeling central to exposure assessment. Planar multilayer skin models are commonly used, although their validity at higher mmWave frequencies is still under debate. This study investigates the impact of skin geometry on electromagnetic field distribution at 26 GHz by comparing planar and non-planar multilayer skin models under identical dielectric and exposure conditions. Electric field distributions and surface-based electromagnetic quantities are analyzed to isolate geometry-driven effects. The results highlight localized field and power density variations associated with non-planar interfaces, suggesting that planar models may not fully capture geometry-induced near-surface effects at FR2 frequencies.

Impact of skin geometry on electromagnetic fields distribution at 26 GHz / Conforti, A., Dolciotti, N., Colella, M., Barbieri, I., Apollonio, F., Liberti, M.. - (2026). (XXXVIth URSI General Assembly and Scientific Symposium (URSIGASS2026) Krakow; Poland ) [10.46620/URSIGASS26/LVOR8484].

Impact of skin geometry on electromagnetic fields distribution at 26 GHz

Alessandra Conforti;Noemi Dolciotti;Micol Colella;Ilaria Barbieri;Francesca Apollonio;Micaela Liberti
2026

Abstract

At millimeter-wave frequencies, electromagnetic energy deposition in the human body is confined to superficial tissues, making skin modeling central to exposure assessment. Planar multilayer skin models are commonly used, although their validity at higher mmWave frequencies is still under debate. This study investigates the impact of skin geometry on electromagnetic field distribution at 26 GHz by comparing planar and non-planar multilayer skin models under identical dielectric and exposure conditions. Electric field distributions and surface-based electromagnetic quantities are analyzed to isolate geometry-driven effects. The results highlight localized field and power density variations associated with non-planar interfaces, suggesting that planar models may not fully capture geometry-induced near-surface effects at FR2 frequencies.
2026
XXXVIth URSI General Assembly and Scientific Symposium (URSIGASS2026)
dosimetry; electromagnetic fields; skin
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
Impact of skin geometry on electromagnetic fields distribution at 26 GHz / Conforti, A., Dolciotti, N., Colella, M., Barbieri, I., Apollonio, F., Liberti, M.. - (2026). (XXXVIth URSI General Assembly and Scientific Symposium (URSIGASS2026) Krakow; Poland ) [10.46620/URSIGASS26/LVOR8484].
File allegati a questo prodotto
File Dimensione Formato  
Conforti_Impact_2026.pdf

accesso aperto

Tipologia: Documento in Post-print (versione successiva alla peer review e accettata per la pubblicazione)
Licenza: Creative commons
Dimensione 2.65 MB
Formato Adobe PDF
2.65 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.