Real-time in vitro bioelectromagnetic experimentation under radiofrequency (RF) exposure requires strict control of the conditions delivered to the sample, especially when coupled with sensitive electrophysiological recordings. Although dosimetric characterization of exposure systems is increasingly reported, the measurement chain and protocol used to set, monitor, and verify the delivered RF power are rarely described in sufficient detail, leaving a gap between system dosimetry and daily practice. This work presents a methodology for characterizing and verifying the RF measurement chain upstream of a real-time in vitro exposure system at 5G Frequency Range 1 (FR1) frequencies, from signal generation to the exposure device. Scattering-parameter characterization of the chain components is combined with continuous power monitoring to translate a target Specific Absorption Rate (SAR) into the corresponding generator setting. A bottom-up uncertainty budget is reported, and the measurement model is verified experimentally at 3.5 GHz on a representative chain configuration, with the deviation between predicted and measured reflected power remaining within the estimated expanded uncertainty. As a complementary check, real-time temperature monitoring confirms the absence of detectable thermal drift under a representative low-power exposure condition. Rather than system-specific dosimetric results, this work provides a reusable procedure for controlled and traceable RF exposure conditions.

Metrological verification of RF measurement chains for real-time in vitro bioelectromagnetic experiments / Pisano, C., Dolciotti, N., Paffi, A., Cioni, M., Guerra, G., Zironi, I., Remondini, D., Aicardi, G., Liberti, M., Apollonio, F.. - In: ELECTRONICS. - ISSN 2079-9292. - 15:19(2026). [10.3390/electronics15194365]

Metrological verification of RF measurement chains for real-time in vitro bioelectromagnetic experiments

Pisano, Carmen;Dolciotti, Noemi;Paffi, Alessandra;Liberti, Micaela;Apollonio, Francesca
2026

Abstract

Real-time in vitro bioelectromagnetic experimentation under radiofrequency (RF) exposure requires strict control of the conditions delivered to the sample, especially when coupled with sensitive electrophysiological recordings. Although dosimetric characterization of exposure systems is increasingly reported, the measurement chain and protocol used to set, monitor, and verify the delivered RF power are rarely described in sufficient detail, leaving a gap between system dosimetry and daily practice. This work presents a methodology for characterizing and verifying the RF measurement chain upstream of a real-time in vitro exposure system at 5G Frequency Range 1 (FR1) frequencies, from signal generation to the exposure device. Scattering-parameter characterization of the chain components is combined with continuous power monitoring to translate a target Specific Absorption Rate (SAR) into the corresponding generator setting. A bottom-up uncertainty budget is reported, and the measurement model is verified experimentally at 3.5 GHz on a representative chain configuration, with the deviation between predicted and measured reflected power remaining within the estimated expanded uncertainty. As a complementary check, real-time temperature monitoring confirms the absence of detectable thermal drift under a representative low-power exposure condition. Rather than system-specific dosimetric results, this work provides a reusable procedure for controlled and traceable RF exposure conditions.
2026
scattering parameters; measurement uncertainty; dosimetry; 5G; frequency range 1 (FR1); specific absorption rate (SAR); power monitoring; reproducibility
01 Pubblicazione su rivista::01a Articolo in rivista
Metrological verification of RF measurement chains for real-time in vitro bioelectromagnetic experiments / Pisano, C., Dolciotti, N., Paffi, A., Cioni, M., Guerra, G., Zironi, I., Remondini, D., Aicardi, G., Liberti, M., Apollonio, F.. - In: ELECTRONICS. - ISSN 2079-9292. - 15:19(2026). [10.3390/electronics15194365]
File allegati a questo prodotto
File Dimensione Formato  
Pisano_Metrological-verification-of_2026.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 9.49 MB
Formato Adobe PDF
9.49 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1777787
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact