The early detection and monitoring of stress-induced damage in concrete is a key goal for nondestructive evaluation and structural health monitoring of civil structures. Both linear and nonlinear ultrasonic testing methods have been developed for this purpose. The Ultrasonic Pulse Velocity (UPV) test is the standard linear technique and is reliable and easy to use, but it typically detects defects only after micro-cracks coalesce or grow beyond a threshold size. To enable earlier detection, features extracted from the nonlinear ultrasonic response—especially harmonics generation—have been proposed. However, these approaches often require complex measurement protocols, and their signal-to-noise ratio (SNR) can be limited. In this study, we leverage an exponential swept-sine pulse-compression (ESS–PuC) procedure to characterize both linear and nonlinear responses from a single measurement. We define and extract several features from both responses, and use them to monitor micro-crack initiation and growth in concrete specimens under gradually increasing compressive load. This enables a qualitative comparison of their characteristics and performance in detecting crack formation.

Comparison of linear and nonlinear ultrasonic features for the analysis of concrete under compression / Medaglia, F., Candamano, S., Iorfida, A., Laureti, S., Martino, D., Porco, G., Ricci, M., Zito, R.. - In: APPLIED SCIENCES. - ISSN 2076-3417. - 16:6(2026). [10.3390/app16062715]

Comparison of linear and nonlinear ultrasonic features for the analysis of concrete under compression

Marco Ricci
Penultimo
;
2026

Abstract

The early detection and monitoring of stress-induced damage in concrete is a key goal for nondestructive evaluation and structural health monitoring of civil structures. Both linear and nonlinear ultrasonic testing methods have been developed for this purpose. The Ultrasonic Pulse Velocity (UPV) test is the standard linear technique and is reliable and easy to use, but it typically detects defects only after micro-cracks coalesce or grow beyond a threshold size. To enable earlier detection, features extracted from the nonlinear ultrasonic response—especially harmonics generation—have been proposed. However, these approaches often require complex measurement protocols, and their signal-to-noise ratio (SNR) can be limited. In this study, we leverage an exponential swept-sine pulse-compression (ESS–PuC) procedure to characterize both linear and nonlinear responses from a single measurement. We define and extract several features from both responses, and use them to monitor micro-crack initiation and growth in concrete specimens under gradually increasing compressive load. This enables a qualitative comparison of their characteristics and performance in detecting crack formation.
2026
ultrasonic NDT; nonlinear ultrasonic methods; concrete; load-induced damage; pulse compression; exponential swept-sine identification method
01 Pubblicazione su rivista::01a Articolo in rivista
Comparison of linear and nonlinear ultrasonic features for the analysis of concrete under compression / Medaglia, F., Candamano, S., Iorfida, A., Laureti, S., Martino, D., Porco, G., Ricci, M., Zito, R.. - In: APPLIED SCIENCES. - ISSN 2076-3417. - 16:6(2026). [10.3390/app16062715]
File allegati a questo prodotto
File Dimensione Formato  
Medaglia_Comparison_2026.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 10.66 MB
Formato Adobe PDF
10.66 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.