Purpose: To examine pre-cut factors associated with post-cut graft thickness in ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) prepared with a mechanical microkeratome system and to develop a nomogram to support blade selection. Methods: Donor corneas processed at a single eye bank were included. All tissues were dissected using a standardised mechanical microkeratome protocol with fixed pressure and cutting speed. Pre-cut variables included central pachymetry, microkeratome blade size, endothelial cell density, cause of death and demographic characteristics. Multivariable regression was used to evaluate predictors of post-cut graft thickness. Adjusted predictions across the observed pachymetry range were generated to construct a nomogram estimating expected graft thickness for each blade. Results: A total of 107 donor corneas were analysed. Mean post-cut graft thickness was 92.7±24.3 µm. In the multivariable model, blade size (p<0.001) and pre-cut pachymetry (p<0.001) showed the strongest associations with graft thickness, accounting together for approximately 45.7% of model variance. The cut-to-blade ratio analysis indicated that all blades produced cuts deeper than their nominal thickness, with ratios increasing across blade sizes. The resulting nomogram enables selection of the blade more likely to achieve grafts within the 70–100 µm range based on the donor’s initial pachymetry. Conclusions: Blade size and initial pachymetry show measurable associations with post-cut graft thickness in UT-DSAEK prepared under standardised mechanical conditions. The proposed nomogram offers a practical tool to assist in selecting the blade expected to achieve ultrathin grafts with greater reproducibility.

Predicting graft thickness in ultrathin DSAEK using a mechanical microkeratome system / Visioli, G., Lucchino, L., Scarinci, F., Jünger, V., Pocobelli, G., Lodato, G., Falchi, A., Marenco, M., Lambiase, A., Pocobelli, A., Anna Maria Colabelli Gisoldi, R.. - In: BMJ OPEN OPHTHALMOLOGY. - ISSN 2397-3269. - 11:3(2026), pp. 1-8. [10.1136/bmjophth-2026-002721]

Predicting graft thickness in ultrathin DSAEK using a mechanical microkeratome system

Giacomo Visioli
Co-primo
Writing – Original Draft Preparation
;
Luca Lucchino
Co-primo
Writing – Original Draft Preparation
;
Fabio Scarinci
Secondo
Methodology
;
Giulio Pocobelli
Writing – Review & Editing
;
Antonella Falchi
Investigation
;
Marco Marenco
Supervision
;
Alessandro Lambiase
Resources
;
2026

Abstract

Purpose: To examine pre-cut factors associated with post-cut graft thickness in ultrathin Descemet stripping automated endothelial keratoplasty (UT-DSAEK) prepared with a mechanical microkeratome system and to develop a nomogram to support blade selection. Methods: Donor corneas processed at a single eye bank were included. All tissues were dissected using a standardised mechanical microkeratome protocol with fixed pressure and cutting speed. Pre-cut variables included central pachymetry, microkeratome blade size, endothelial cell density, cause of death and demographic characteristics. Multivariable regression was used to evaluate predictors of post-cut graft thickness. Adjusted predictions across the observed pachymetry range were generated to construct a nomogram estimating expected graft thickness for each blade. Results: A total of 107 donor corneas were analysed. Mean post-cut graft thickness was 92.7±24.3 µm. In the multivariable model, blade size (p<0.001) and pre-cut pachymetry (p<0.001) showed the strongest associations with graft thickness, accounting together for approximately 45.7% of model variance. The cut-to-blade ratio analysis indicated that all blades produced cuts deeper than their nominal thickness, with ratios increasing across blade sizes. The resulting nomogram enables selection of the blade more likely to achieve grafts within the 70–100 µm range based on the donor’s initial pachymetry. Conclusions: Blade size and initial pachymetry show measurable associations with post-cut graft thickness in UT-DSAEK prepared under standardised mechanical conditions. The proposed nomogram offers a practical tool to assist in selecting the blade expected to achieve ultrathin grafts with greater reproducibility.
2026
corneal transplant; DSAEK; microkeratome; eye bank; normogram
01 Pubblicazione su rivista::01a Articolo in rivista
Predicting graft thickness in ultrathin DSAEK using a mechanical microkeratome system / Visioli, G., Lucchino, L., Scarinci, F., Jünger, V., Pocobelli, G., Lodato, G., Falchi, A., Marenco, M., Lambiase, A., Pocobelli, A., Anna Maria Colabelli Gisoldi, R.. - In: BMJ OPEN OPHTHALMOLOGY. - ISSN 2397-3269. - 11:3(2026), pp. 1-8. [10.1136/bmjophth-2026-002721]
File allegati a questo prodotto
File Dimensione Formato  
Visioli_Predicting graft thickness_2026.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 1.19 MB
Formato Adobe PDF
1.19 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1775670
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? ND
social impact