Characterizing low-energy, keV-range nuclear recoils near the detector threshold is one of the major challenges for large direct dark matter detectors. To that end, we have successfully used a Yttrium-Beryllium photoneutron source that emits 152 keV neutrons for the calibration of the light and charge yields of the XENONnT experiment for the first time. After data selection, we accumulated 474 events from 183 hours of exposure with this source. The expected background was 55 ±12 accidental coincidence events, estimated using a dedicated 152 hour background calibration run with a Yttrium-PVC gamma-only source and data-driven modeling. From these calibrations, we extracted the light (charge) yield for liquid xenon at our field strength of 23  V/cm between 0.3 (0.7) keV_NR and 5.0  keV_NR. This calibration is crucial for accurately measuring the solar 8B neutrino coherent elastic neutrino-nucleus scattering and searching for light dark matter particles with masses below 12  GeV/c².

Low-energy nuclear recoil calibration of XENONnT with a 88YBe photoneutron source / Aprile, E., Aalbers, J., Abe, K., Ahmed Maouloud, S., Althueser, L., Andrieu, B., Angelino, E., Antón Martin, D., Arneodo, F., Baudis, L., Bazyk, M., Bellagamba, L., Biondi, R., Bismark, A., Boese, K., Brown, A., Bruno, G., Budnik, R., Cai, C., Capelli, C., et al.. - In: PHYSICAL REVIEW D. - ISSN 2470-0010. - 113:11(2026), pp. 1-14. [10.1103/rsl9-j1ky]

Low-energy nuclear recoil calibration of XENONnT with a 88YBe photoneutron source

Capelli, C.;
2026

Abstract

Characterizing low-energy, keV-range nuclear recoils near the detector threshold is one of the major challenges for large direct dark matter detectors. To that end, we have successfully used a Yttrium-Beryllium photoneutron source that emits 152 keV neutrons for the calibration of the light and charge yields of the XENONnT experiment for the first time. After data selection, we accumulated 474 events from 183 hours of exposure with this source. The expected background was 55 ±12 accidental coincidence events, estimated using a dedicated 152 hour background calibration run with a Yttrium-PVC gamma-only source and data-driven modeling. From these calibrations, we extracted the light (charge) yield for liquid xenon at our field strength of 23  V/cm between 0.3 (0.7) keV_NR and 5.0  keV_NR. This calibration is crucial for accurately measuring the solar 8B neutrino coherent elastic neutrino-nucleus scattering and searching for light dark matter particles with masses below 12  GeV/c².
2026
dark matter; direct detection; xenon; calibration; photoneutron source
01 Pubblicazione su rivista::01a Articolo in rivista
Low-energy nuclear recoil calibration of XENONnT with a 88YBe photoneutron source / Aprile, E., Aalbers, J., Abe, K., Ahmed Maouloud, S., Althueser, L., Andrieu, B., Angelino, E., Antón Martin, D., Arneodo, F., Baudis, L., Bazyk, M., Bellagamba, L., Biondi, R., Bismark, A., Boese, K., Brown, A., Bruno, G., Budnik, R., Cai, C., Capelli, C., et al.. - In: PHYSICAL REVIEW D. - ISSN 2470-0010. - 113:11(2026), pp. 1-14. [10.1103/rsl9-j1ky]
File allegati a questo prodotto
File Dimensione Formato  
Aprile_Low-energy-nuclear_2026.pdf

accesso aperto

Note: Articolo su rivista
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 2.68 MB
Formato Adobe PDF
2.68 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1773995
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus ND
  • ???jsp.display-item.citation.isi??? 3
social impact