The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have been screened with gamma-ray spectroscopy, mass spectrometry, and 222Rn emanation measurements. Furthermore, the cleanliness procedures applied to remove or mitigate surface contamination of detector materials are described. Screening results, used as inputs for a XENONnT Monte Carlo simulation, predict a reduction of materials background (~17%) with respect to its predecessor XENON1T. Through radon emanation measurements, the expected 222Rn activity concentration in XENONnT is determined to be 4.2 (+0.5−0.7) μBq/kg, a factor three lower with respect to XENON1T. This radon concentration will be further suppressed by means of the novel radon distillation system.

Material radiopurity control in the XENONnT experiment / Aprile, E., Abe, K., Agostini, F., Ahmed Maouloud, S., Alfonsi, M., Althueser, L., Angelino, E., Angevaare, J.R., Antochi, V.C., Antón Martin, D., Arneodo, F., Baudis, L., Baxter, A.L., Bellagamba, L., Biondi, R., Bismark, A., Brown, A., Bruenner, S., Bruno, G., Budnik, R., et al.. - In: THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS. - ISSN 1434-6044. - 82:7(2022), pp. 1-21. [10.1140/epjc/s10052-022-10345-6]

Material radiopurity control in the XENONnT experiment

Capelli, C.;
2022

Abstract

The selection of low-radioactive construction materials is of the utmost importance for rare-event searches and thus critical to the XENONnT experiment. Results of an extensive radioassay program are reported, in which material samples have been screened with gamma-ray spectroscopy, mass spectrometry, and 222Rn emanation measurements. Furthermore, the cleanliness procedures applied to remove or mitigate surface contamination of detector materials are described. Screening results, used as inputs for a XENONnT Monte Carlo simulation, predict a reduction of materials background (~17%) with respect to its predecessor XENON1T. Through radon emanation measurements, the expected 222Rn activity concentration in XENONnT is determined to be 4.2 (+0.5−0.7) μBq/kg, a factor three lower with respect to XENON1T. This radon concentration will be further suppressed by means of the novel radon distillation system.
2022
gamma spectroscopy; mass spectrometry; radon emanation; surface treatment; detector cleanliness
01 Pubblicazione su rivista::01a Articolo in rivista
Material radiopurity control in the XENONnT experiment / Aprile, E., Abe, K., Agostini, F., Ahmed Maouloud, S., Alfonsi, M., Althueser, L., Angelino, E., Angevaare, J.R., Antochi, V.C., Antón Martin, D., Arneodo, F., Baudis, L., Baxter, A.L., Bellagamba, L., Biondi, R., Bismark, A., Brown, A., Bruenner, S., Bruno, G., Budnik, R., et al.. - In: THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS. - ISSN 1434-6044. - 82:7(2022), pp. 1-21. [10.1140/epjc/s10052-022-10345-6]
File allegati a questo prodotto
File Dimensione Formato  
Aprile_Material-radiopurity-control_2022.pdf

accesso aperto

Note: Articolo su rivista
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 1.23 MB
Formato Adobe PDF
1.23 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1773629
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 46
  • ???jsp.display-item.citation.isi??? 48
social impact