The XENON1T liquid xenon time projection chamber is the most sensitive detector built to date for the measurement of direct interactions of weakly interacting massive particles with normal matter. The data acquisition system (DAQ) is constructed from commercial, open source, and custom components to digitize signals from the detector and store them for later analysis. The system achieves an extremely low signal threshold by triggering each channel independently, achieving a single photoelectron acceptance of (93 ± 3)%, and deferring the global trigger to a later, software stage. The event identification is based on MongoDB database queries and has over 98% efficiency at recognizing interactions at the analysis threshold in the center of the target. A readout bandwidth over 300 MB/s is reached in calibration modes and is further expandable via parallelization. This DAQ system was successfully used during three years of operation of XENON1T.

The XENON1T data acquisition system / Aprile, E., Aalbers, J., Agostini, F., Alfonsi, M., Althueser, L., Amaro, F.D., Antochi, V.C., Arneodo, F., Barge, D., Baudis, L., Bauermeister, B., Bellagamba, L., Benabderrahmane, M.L., Berger, T., Breur, P.A., Brown, A., Brown, E., Bruenner, S., Bruno, G., Budnik, R., et al.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 14:07(2019), pp. 1-18. [10.1088/1748-0221/14/07/P07016]

The XENON1T data acquisition system

Capelli, C.;
2019

Abstract

The XENON1T liquid xenon time projection chamber is the most sensitive detector built to date for the measurement of direct interactions of weakly interacting massive particles with normal matter. The data acquisition system (DAQ) is constructed from commercial, open source, and custom components to digitize signals from the detector and store them for later analysis. The system achieves an extremely low signal threshold by triggering each channel independently, achieving a single photoelectron acceptance of (93 ± 3)%, and deferring the global trigger to a later, software stage. The event identification is based on MongoDB database queries and has over 98% efficiency at recognizing interactions at the analysis threshold in the center of the target. A readout bandwidth over 300 MB/s is reached in calibration modes and is further expandable via parallelization. This DAQ system was successfully used during three years of operation of XENON1T.
2019
dark matter detectors; data acquisition concepts; trigger concepts and systems; control and monitor systems online
01 Pubblicazione su rivista::01a Articolo in rivista
The XENON1T data acquisition system / Aprile, E., Aalbers, J., Agostini, F., Alfonsi, M., Althueser, L., Amaro, F.D., Antochi, V.C., Arneodo, F., Barge, D., Baudis, L., Bauermeister, B., Bellagamba, L., Benabderrahmane, M.L., Berger, T., Breur, P.A., Brown, A., Brown, E., Bruenner, S., Bruno, G., Budnik, R., et al.. - In: JOURNAL OF INSTRUMENTATION. - ISSN 1748-0221. - 14:07(2019), pp. 1-18. [10.1088/1748-0221/14/07/P07016]
File allegati a questo prodotto
File Dimensione Formato  
Aprile_The-XENON1T-data_2019.pdf

solo gestori archivio

Note: Articolo su rivista
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 1.91 MB
Formato Adobe PDF
1.91 MB Adobe PDF   Contatta l'autore