Xenon dual-phase time projection chambers designed to search for weakly interacting massive particles have so far shown a relative energy resolution which degrades with energy above ~200 keV due to the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of ¹³⁶Xe at its Q value, Qᵦᵦ ≃ 2.46 MeV. For the XENON1T dual-phase time projection chamber, we demonstrate that the relative energy resolution at 1 σ/μ is as low as (0.80±0.02) % in its one-ton fiducial mass, and for single-site interactions at Qᵦᵦ. We also present a new signal correction method to rectify the saturation effects of the signal readout system, resulting in more accurate position reconstruction and indirectly improving the energy resolution. The very good result achieved in XENON1T opens up new windows for the xenon dual-phase dark matter detectors to simultaneously search for other rare events.

Energy resolution and linearity of XENON1T in the MeV energy range / Aprile, E., Aalbers, J., Agostini, F., Alfonsi, M., Althueser, L., Amaro, F.D., Antochi, V.C., Angelino, E., Angevaare, J., Arneodo, F., Barge, D., Baudis, L., Bauermeister, B., Bellagamba, L., Benabderrahmane, M.L., Berger, T., Breur, P.A., Brown, A., Brown, E., Bruenner, S., et al.. - In: THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS. - ISSN 1434-6044. - 80:8(2020), pp. 1-9. [10.1140/epjc/s10052-020-8284-0]

Energy resolution and linearity of XENON1T in the MeV energy range

Capelli, C.
;
2020

Abstract

Xenon dual-phase time projection chambers designed to search for weakly interacting massive particles have so far shown a relative energy resolution which degrades with energy above ~200 keV due to the saturation effects. This has limited their sensitivity in the search for rare events like the neutrinoless double-beta decay of ¹³⁶Xe at its Q value, Qᵦᵦ ≃ 2.46 MeV. For the XENON1T dual-phase time projection chamber, we demonstrate that the relative energy resolution at 1 σ/μ is as low as (0.80±0.02) % in its one-ton fiducial mass, and for single-site interactions at Qᵦᵦ. We also present a new signal correction method to rectify the saturation effects of the signal readout system, resulting in more accurate position reconstruction and indirectly improving the energy resolution. The very good result achieved in XENON1T opens up new windows for the xenon dual-phase dark matter detectors to simultaneously search for other rare events.
2020
dark matter; direct detection; xenon; energy resolution
01 Pubblicazione su rivista::01a Articolo in rivista
Energy resolution and linearity of XENON1T in the MeV energy range / Aprile, E., Aalbers, J., Agostini, F., Alfonsi, M., Althueser, L., Amaro, F.D., Antochi, V.C., Angelino, E., Angevaare, J., Arneodo, F., Barge, D., Baudis, L., Bauermeister, B., Bellagamba, L., Benabderrahmane, M.L., Berger, T., Breur, P.A., Brown, A., Brown, E., Bruenner, S., et al.. - In: THE EUROPEAN PHYSICAL JOURNAL. C, PARTICLES AND FIELDS. - ISSN 1434-6044. - 80:8(2020), pp. 1-9. [10.1140/epjc/s10052-020-8284-0]
File allegati a questo prodotto
File Dimensione Formato  
Aprile_Energy-resolution_2020.pdf

accesso aperto

Note: Articolo su rivista
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 2.2 MB
Formato Adobe PDF
2.2 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1773414
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 68
  • ???jsp.display-item.citation.isi??? 64
social impact