Introduction: Indocyanine green fluorescence angiography (ICG-FA) is commonly used in general surgery, but its use in bariatric surgery is still marginal. Moreover, post-operative leaks remain a dramatic complication after this surgery and the leak tests available have poor performance preventing them. The aim of the present paper is to assess the use and utility of a new innovative technology based on quantitative measures of fluorescence signal intensity. Material and methods: From January 2022 to June 2022, 40 consecutive patients with a median age of 51 years and a preoperative median body mass index of 45.2 kg/m2 underwent bariatric surgery with quantitative ICG fluorescence angiography in our center. Two different types of surgery, based on the multidisciplinary evaluation, were performed: laparoscopic sleeve gastrectomy (LSG) and one anastomosis gastric bypass (OAGB). For ICG visualization, quantitative laparoscopic ICG platform was used to identify the vascular supply. Results: Thirteen patients underwent LSG and 27 patients underwent OAGB. ICG was performed in all patients with no adverse events. An adequate and satisfactory blood supply was assessed in each case. No case of post-operative leak was detected. Conclusions: The quantitative ICG-FA seems to be a useful and promising tool for the prevention of complications in bariatric surgery but further studies are mandatory.

Use of quantitative indocyanine green near-infrared fluorescence imaging in bariatric surgery: early results / Biancucci, A., Fassari, A., Lucchese, S., Santoro, E., Lirici, M.M.. - In: MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES. - ISSN 1364-5706. - 32:5(2023), pp. 249-255. [10.1080/13645706.2023.2197049]

Use of quantitative indocyanine green near-infrared fluorescence imaging in bariatric surgery: early results

Biancucci, Andrea;Fassari, Alessia
Secondo
Writing – Original Draft Preparation
;
Lucchese, Sara;Santoro, Emanuele;Lirici, Marco Maria
2023

Abstract

Introduction: Indocyanine green fluorescence angiography (ICG-FA) is commonly used in general surgery, but its use in bariatric surgery is still marginal. Moreover, post-operative leaks remain a dramatic complication after this surgery and the leak tests available have poor performance preventing them. The aim of the present paper is to assess the use and utility of a new innovative technology based on quantitative measures of fluorescence signal intensity. Material and methods: From January 2022 to June 2022, 40 consecutive patients with a median age of 51 years and a preoperative median body mass index of 45.2 kg/m2 underwent bariatric surgery with quantitative ICG fluorescence angiography in our center. Two different types of surgery, based on the multidisciplinary evaluation, were performed: laparoscopic sleeve gastrectomy (LSG) and one anastomosis gastric bypass (OAGB). For ICG visualization, quantitative laparoscopic ICG platform was used to identify the vascular supply. Results: Thirteen patients underwent LSG and 27 patients underwent OAGB. ICG was performed in all patients with no adverse events. An adequate and satisfactory blood supply was assessed in each case. No case of post-operative leak was detected. Conclusions: The quantitative ICG-FA seems to be a useful and promising tool for the prevention of complications in bariatric surgery but further studies are mandatory.
2023
Quantitative Indocyanine Green (ICG); bariatric surgery; laparoscopic sleeve gastrectomy (LSG); leak; one anastomosis gastric bypass (OAGB)
01 Pubblicazione su rivista::01a Articolo in rivista
Use of quantitative indocyanine green near-infrared fluorescence imaging in bariatric surgery: early results / Biancucci, A., Fassari, A., Lucchese, S., Santoro, E., Lirici, M.M.. - In: MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES. - ISSN 1364-5706. - 32:5(2023), pp. 249-255. [10.1080/13645706.2023.2197049]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1770676
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 2
  • ???jsp.display-item.citation.isi??? 2
social impact