Purpose Monte Carlo (MC) simulations provide gold-standard accuracy for carbon ion therapy dose calculations but are computationally intensive, limiting their use in adaptive workflows. Analytical pencil beam algorithms offer speed but reduced accuracy in heterogeneous tissues. This study develops the first AI-based dose engine capable of predicting relative biological effectiveness-weighted doses. Absorbed dose, α, and β parameters for optimization are calculated at MC-level accuracy with a drastically reduced computational time. Materials and Methods We extended the transformer-based DoTA architecture to predict absorbed dose (C-DoTA-d), α (C-DoTA-α), and β (C-DoTA-β), introducing a cross-attention mechanism for α and β to combine dose and energy inputs. The training dataset consisted of approximately 70 000 pencil beams from 187 head-and-neck patients, with ground-truth values obtained using the GPU-accelerated MC toolkit FRED. Performance was evaluated on an independent test set using gamma pass rate (1%/1 mm), depth-dose, and isodose contour Dice coefficients. MC dropout-based uncertainty analysis was performed. Results Median gamma pass rates exceeded 98% for all predictions (99.76% for dose, 99.14% for α, 98.74% for β), with minima above 85% in the most heterogeneous anatomies. The Dice coefficient was 0.95 for 1% isodose contours, with slightly reduced agreement in high-gradient regions. Compared to MC FRED, inference was over 400× faster (0.032 vs 14 seconds per pencil beam) while maintaining accuracy. Uncertainty analysis showed high stability, with mean standard deviations below 0.5% for all models. Conclusions This AI-based dose engine achieves MC-quality predictions of absorbed dose and relative biological effectiveness model parameters in ∼30 ms per beamlet. Its speed and accuracy support online adaptive planning, paving the way for more effective carbon ion therapy workflows. Future work will expand to additional anatomical sites, beam geometries, and clinical beamlines.

An artificial intelligence dose engine for fast carbon ion treatment planning / Quarz, A.; De Gregorio, A.; Franciosini, G.; Schiavi, A.; Perkó, Z.; Volz, L.; Hoog Antink, C.; Patera, V.; Durante, M.; Graeff, C.. - In: INTERNATIONAL JOURNAL OF PARTICLE THERAPY. - ISSN 2331-5180. - 19:(2026), pp. 1-8. [10.1016/j.ijpt.2026.101309]

An artificial intelligence dose engine for fast carbon ion treatment planning

De Gregorio, A.;Franciosini, G.;Schiavi, A.;Patera, V.;
2026

Abstract

Purpose Monte Carlo (MC) simulations provide gold-standard accuracy for carbon ion therapy dose calculations but are computationally intensive, limiting their use in adaptive workflows. Analytical pencil beam algorithms offer speed but reduced accuracy in heterogeneous tissues. This study develops the first AI-based dose engine capable of predicting relative biological effectiveness-weighted doses. Absorbed dose, α, and β parameters for optimization are calculated at MC-level accuracy with a drastically reduced computational time. Materials and Methods We extended the transformer-based DoTA architecture to predict absorbed dose (C-DoTA-d), α (C-DoTA-α), and β (C-DoTA-β), introducing a cross-attention mechanism for α and β to combine dose and energy inputs. The training dataset consisted of approximately 70 000 pencil beams from 187 head-and-neck patients, with ground-truth values obtained using the GPU-accelerated MC toolkit FRED. Performance was evaluated on an independent test set using gamma pass rate (1%/1 mm), depth-dose, and isodose contour Dice coefficients. MC dropout-based uncertainty analysis was performed. Results Median gamma pass rates exceeded 98% for all predictions (99.76% for dose, 99.14% for α, 98.74% for β), with minima above 85% in the most heterogeneous anatomies. The Dice coefficient was 0.95 for 1% isodose contours, with slightly reduced agreement in high-gradient regions. Compared to MC FRED, inference was over 400× faster (0.032 vs 14 seconds per pencil beam) while maintaining accuracy. Uncertainty analysis showed high stability, with mean standard deviations below 0.5% for all models. Conclusions This AI-based dose engine achieves MC-quality predictions of absorbed dose and relative biological effectiveness model parameters in ∼30 ms per beamlet. Its speed and accuracy support online adaptive planning, paving the way for more effective carbon ion therapy workflows. Future work will expand to additional anatomical sites, beam geometries, and clinical beamlines.
2026
carbon therapy; deep-learning; dose engine; RBE-weighted dose; treatment planning
01 Pubblicazione su rivista::01a Articolo in rivista
An artificial intelligence dose engine for fast carbon ion treatment planning / Quarz, A.; De Gregorio, A.; Franciosini, G.; Schiavi, A.; Perkó, Z.; Volz, L.; Hoog Antink, C.; Patera, V.; Durante, M.; Graeff, C.. - In: INTERNATIONAL JOURNAL OF PARTICLE THERAPY. - ISSN 2331-5180. - 19:(2026), pp. 1-8. [10.1016/j.ijpt.2026.101309]
File allegati a questo prodotto
File Dimensione Formato  
Quarz_An-artificial-intelligence_2026.pdf

accesso aperto

Note: Articolo su rivista
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 3.55 MB
Formato Adobe PDF
3.55 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1763944
Citazioni
  • ???jsp.display-item.citation.pmc??? 1
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact