This paper reports the preliminary results of the “Push ’o ver” research project, which investigated the in situ experimental behaviour of two twin existing masonry buildings, one as built, and one strengthened with composite reinforced mortar (CRM). Originally the two-storey buildings were made of 250-mm-thick, solid-fired-clay, lime-mortar brickwork. CRM is made with a lime and cement mortar as well as a glass fibre reinforced polymer (GFRP) mesh. Additionally, GFRP angle elements are present at corners and GFRP connectors tie the two CRM layers or a single CRM layer and the brickwork. In fact, the CRM system is applied on both wall sides at ground storey and on external one only at the upper storey. The preliminary comparison between the two buildings allows emphasizing the effectiveness of the intervention. The experimental behaviour of both structures is reasonably captured by the frame-equivalent numerical modelling approach, both in terms of ultimate capacity and failure mechanisms.

IN SITU PUSHOVER TESTS ON UNSTRENGTHENED AND CRM STRENGTHENED MASONRY BUILDINGS. PRELIMINARY RESULTS / Morici, M.; Micozzi, F.; Gioiella, L.; Zona, A.; Dudine, A.; Passerino, C. R.; Grassia, S.; Clemente, P.; Buffarini, G.; Liberatore, D.; Addessi, D.; Sorrentino, L.. - 2024:(2024), pp. 1-11. ( 18th World Conference on Earthquake Engineering Milan, Italy ).

IN SITU PUSHOVER TESTS ON UNSTRENGTHENED AND CRM STRENGTHENED MASONRY BUILDINGS. PRELIMINARY RESULTS

Liberatore D.;Addessi D.;Sorrentino L.
2024

Abstract

This paper reports the preliminary results of the “Push ’o ver” research project, which investigated the in situ experimental behaviour of two twin existing masonry buildings, one as built, and one strengthened with composite reinforced mortar (CRM). Originally the two-storey buildings were made of 250-mm-thick, solid-fired-clay, lime-mortar brickwork. CRM is made with a lime and cement mortar as well as a glass fibre reinforced polymer (GFRP) mesh. Additionally, GFRP angle elements are present at corners and GFRP connectors tie the two CRM layers or a single CRM layer and the brickwork. In fact, the CRM system is applied on both wall sides at ground storey and on external one only at the upper storey. The preliminary comparison between the two buildings allows emphasizing the effectiveness of the intervention. The experimental behaviour of both structures is reasonably captured by the frame-equivalent numerical modelling approach, both in terms of ultimate capacity and failure mechanisms.
2024
18th World Conference on Earthquake Engineering
.
04 Pubblicazione in atti di convegno::04b Atto di convegno in volume
IN SITU PUSHOVER TESTS ON UNSTRENGTHENED AND CRM STRENGTHENED MASONRY BUILDINGS. PRELIMINARY RESULTS / Morici, M.; Micozzi, F.; Gioiella, L.; Zona, A.; Dudine, A.; Passerino, C. R.; Grassia, S.; Clemente, P.; Buffarini, G.; Liberatore, D.; Addessi, D.; Sorrentino, L.. - 2024:(2024), pp. 1-11. ( 18th World Conference on Earthquake Engineering Milan, Italy ).
File allegati a questo prodotto
File Dimensione Formato  
Morici_IN SITU PUSHOVER TESTS_2024.pdf

accesso aperto

Note: Articolo principale
Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Tutti i diritti riservati (All rights reserved)
Dimensione 892.69 kB
Formato Adobe PDF
892.69 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1763787
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? ND
social impact