Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications.

Ahmed glaucoma valve implant: surgical technique and complications / Riva, I; Roberti, G; Oddone, F; Konstas, Ag; Quaranta, L.. - In: CLINICAL OPHTHALMOLOGY. - ISSN 1177-5483. - 2017:11(2017), pp. 357-367. [10.2147/OPTH.S104220]

Ahmed glaucoma valve implant: surgical technique and complications

Roberti G
Secondo
;
2017

Abstract

Implantation of Ahmed glaucoma valve is an effective surgical technique to reduce intraocular pressure in patients affected with glaucoma. While in the past, the use of this device was reserved to glaucoma refractory to multiple filtration surgical procedures, up-to-date mounting experience has encouraged its use also as a primary surgery for selected cases. Implantation of Ahmed glaucoma valve can be challenging for the surgeon, especially in patients who already underwent previous multiple surgeries. Several tips have to be acquired by the surgeon, and a long learning curve is always needed. Although the valve mechanism embedded in the Ahmed glaucoma valve decreases the risk of postoperative hypotony-related complications, it does not avoid the need of a careful follow-up. Complications related to this type of surgery include early and late postoperative hypotony, excessive capsule fibrosis around the plate, erosion of the tube or plate edge, and very rarely infection. The aim of this review is to describe surgical technique for Ahmed glaucoma valve implantation and to report related complications.
2017
Ahmed glaucoma valve; complications; glaucoma; glaucoma drainage devices; surgical technique
01 Pubblicazione su rivista::01g Articolo di rassegna (Review)
Ahmed glaucoma valve implant: surgical technique and complications / Riva, I; Roberti, G; Oddone, F; Konstas, Ag; Quaranta, L.. - In: CLINICAL OPHTHALMOLOGY. - ISSN 1177-5483. - 2017:11(2017), pp. 357-367. [10.2147/OPTH.S104220]
File allegati a questo prodotto
File Dimensione Formato  
Riva_Ahmed glaucoma_2017.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 934.47 kB
Formato Adobe PDF
934.47 kB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1763720
Citazioni
  • ???jsp.display-item.citation.pmc??? 60
  • Scopus 120
  • ???jsp.display-item.citation.isi??? 97
social impact