Unitized curtain walls are widely adopted in contemporary architecture for their lightweight construction, aesthetic qualities, ease of installation and high operational performance. They are particularly used in high-rise buildings, where glazed facades are designed to meet a broad range of performance criteria. Well-designed systems tend to perform satisfactorily in normal service conditions, but are more problematic in extreme events. In fact, post-earthquake surveys in seismic-prone regions reveal functionality losses and moderate-to-severe damage to glazed facades, with significant financial, social and environmental consequences. Despite studies on the seismic behaviour of unitized curtain walls, research in this field remains limited. In particular, experimental studies to date rarely assess both serviceability and ultimate limit states, fail to fully characterize the sequence of damage states until collapse and overlook the influence of design choices on the fa & ccedil;ade performance. To address these gaps, an extensive experimental campaign on full-scale unitized curtain walls was conducted to investigate the seismic behaviour of fa & ccedil;ade units, including variations in geometry, joint aspect ratios and type (dry-glazed or wet-glazed), frame detailing. The experiments involved quasi-static and dynamic loading, considering in-plane, out-of-plane and vertical movements. Air infiltration, water leakage and wind resistance tests were conducted before and after low-intensity shaking to assess the post-earthquake fa & ccedil;ade serviceability. Analysis of experimental data highlighted the significant influence of silicone joints on glass rotations and the structural strength hierarchy. Fragility curves were derived from damage observations, which revealed weather-tightness loss at a 0.71% drift ratio and silicone failure in specimens with low-displacement capacity frames.

Seismic Testing and Performance Evaluation of Unitized Curtain Walls / Bianchi, S.; Lori, G.; Hayez, V.; Manara, G.; Schipper, R.; Pampanin, S.; Overend, M.. - In: EARTHQUAKE ENGINEERING AND STRUCTURAL DYNAMICS. - ISSN 1096-9845. - 54:12(2025), pp. 3090-3107. [10.1002/eqe.70017]

Seismic Testing and Performance Evaluation of Unitized Curtain Walls

Lori G.;Manara G.;Pampanin S.;
2025

Abstract

Unitized curtain walls are widely adopted in contemporary architecture for their lightweight construction, aesthetic qualities, ease of installation and high operational performance. They are particularly used in high-rise buildings, where glazed facades are designed to meet a broad range of performance criteria. Well-designed systems tend to perform satisfactorily in normal service conditions, but are more problematic in extreme events. In fact, post-earthquake surveys in seismic-prone regions reveal functionality losses and moderate-to-severe damage to glazed facades, with significant financial, social and environmental consequences. Despite studies on the seismic behaviour of unitized curtain walls, research in this field remains limited. In particular, experimental studies to date rarely assess both serviceability and ultimate limit states, fail to fully characterize the sequence of damage states until collapse and overlook the influence of design choices on the fa & ccedil;ade performance. To address these gaps, an extensive experimental campaign on full-scale unitized curtain walls was conducted to investigate the seismic behaviour of fa & ccedil;ade units, including variations in geometry, joint aspect ratios and type (dry-glazed or wet-glazed), frame detailing. The experiments involved quasi-static and dynamic loading, considering in-plane, out-of-plane and vertical movements. Air infiltration, water leakage and wind resistance tests were conducted before and after low-intensity shaking to assess the post-earthquake fa & ccedil;ade serviceability. Analysis of experimental data highlighted the significant influence of silicone joints on glass rotations and the structural strength hierarchy. Fragility curves were derived from damage observations, which revealed weather-tightness loss at a 0.71% drift ratio and silicone failure in specimens with low-displacement capacity frames.
2025
experimental testing; fragility curves; glazed facades; seismic performance; structural silicone glazing
01 Pubblicazione su rivista::01a Articolo in rivista
Seismic Testing and Performance Evaluation of Unitized Curtain Walls / Bianchi, S.; Lori, G.; Hayez, V.; Manara, G.; Schipper, R.; Pampanin, S.; Overend, M.. - In: EARTHQUAKE ENGINEERING AND STRUCTURAL DYNAMICS. - ISSN 1096-9845. - 54:12(2025), pp. 3090-3107. [10.1002/eqe.70017]
File allegati a questo prodotto
File Dimensione Formato  
Bianchi_Seismic_2025.pdf

accesso aperto

Tipologia: Versione editoriale (versione pubblicata con il layout dell'editore)
Licenza: Creative commons
Dimensione 2.8 MB
Formato Adobe PDF
2.8 MB Adobe PDF

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1756912
Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 0
  • ???jsp.display-item.citation.isi??? 0
social impact