Background: Endoscopic ultrasound (EUS) plays an important role in the diagnosis and staging of thoracic disease. Our report studies the diagnostic performance and clinical impact of EUS fine needle aspiration (FNA) in a homogenous cohort of patients according to the distribution of the enlarged MLNs or pulmonary masses. Methods: We retrospectively reviewed the diagnostic performance of 211 EUS-FNA in 200 consecutive patients with enlarged or PET-positive MLNs and para-mediastinal masses who were referred to our oncological center between January 2019 and May 2020. Results: The overall sensitivity of EUS-FNA was 85% with a corresponding negative predictive value (NPV) of 56% and an accuracy of 87.5%. The sensitivity and accuracy in patients with abnormal MLNs were 81.1% and 84.4%, respectively. In those with para-mediastinal masses, sensitivity and accuracy were 96.4% and 96.8%. The accuracy for both masses and lymph nodes was 100%, and in the LAG (left adrenal gland), it was 66.6%. Conclusions: Our results show that, in patients with suspected mediastinal masses, EUS-FNA is an accurate technique to evaluate all reachable mediastinal nodal stations, including station 5.

Transesophageal Endoscopic Ultrasound Fine Needle Biopsy for the Diagnosis of Mediastinal Masses: A Retrospective Real-World Analysis / Assisi, D.; Gallina, F. T.; Forcella, D.; Taje, R.; Melis, E.; Visca, P.; Pierconti, F.; Venti, E.; Facciolo, F.. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 11:18(2022). [10.3390/jcm11185469]

Transesophageal Endoscopic Ultrasound Fine Needle Biopsy for the Diagnosis of Mediastinal Masses: A Retrospective Real-World Analysis

Gallina F. T.;Forcella D.;Visca P.;Venti E.;Facciolo F.
2022

Abstract

Background: Endoscopic ultrasound (EUS) plays an important role in the diagnosis and staging of thoracic disease. Our report studies the diagnostic performance and clinical impact of EUS fine needle aspiration (FNA) in a homogenous cohort of patients according to the distribution of the enlarged MLNs or pulmonary masses. Methods: We retrospectively reviewed the diagnostic performance of 211 EUS-FNA in 200 consecutive patients with enlarged or PET-positive MLNs and para-mediastinal masses who were referred to our oncological center between January 2019 and May 2020. Results: The overall sensitivity of EUS-FNA was 85% with a corresponding negative predictive value (NPV) of 56% and an accuracy of 87.5%. The sensitivity and accuracy in patients with abnormal MLNs were 81.1% and 84.4%, respectively. In those with para-mediastinal masses, sensitivity and accuracy were 96.4% and 96.8%. The accuracy for both masses and lymph nodes was 100%, and in the LAG (left adrenal gland), it was 66.6%. Conclusions: Our results show that, in patients with suspected mediastinal masses, EUS-FNA is an accurate technique to evaluate all reachable mediastinal nodal stations, including station 5.
2022
endoscopic ultrasound; fine needle aspiration biopsy; mediastinal lymph node; para-mediastinal masses
01 Pubblicazione su rivista::01a Articolo in rivista
Transesophageal Endoscopic Ultrasound Fine Needle Biopsy for the Diagnosis of Mediastinal Masses: A Retrospective Real-World Analysis / Assisi, D.; Gallina, F. T.; Forcella, D.; Taje, R.; Melis, E.; Visca, P.; Pierconti, F.; Venti, E.; Facciolo, F.. - In: JOURNAL OF CLINICAL MEDICINE. - ISSN 2077-0383. - 11:18(2022). [10.3390/jcm11185469]
File allegati a questo prodotto
Non ci sono file associati a questo prodotto.

I documenti in IRIS sono protetti da copyright e tutti i diritti sono riservati, salvo diversa indicazione.

Utilizza questo identificativo per citare o creare un link a questo documento: https://hdl.handle.net/11573/1753681
 Attenzione

Attenzione! I dati visualizzati non sono stati sottoposti a validazione da parte dell'ateneo

Citazioni
  • ???jsp.display-item.citation.pmc??? ND
  • Scopus 4
  • ???jsp.display-item.citation.isi??? ND
social impact